Safety Light Curtain
last update: September 11, 2023
Model | PNP output | F3SJ-E[][][][]P25 |
---|---|---|
NPN output | F3SJ-E[][][][]P25 | |
Sensor type | Type 4 safety light curtain | |
Setting tool connection *1 | Parameter settings: Not available | |
Safety category | Safety purpose of category 4, 3, 2, 1, or B | |
Detection capability | Opaque objects 25 mm in diameter | |
Beam gap (P) | 20 mm | |
Number of beams (n) | 8 to 54 | |
Protective height (PH) | 185 to 1,105 mm | |
Lens diameter | Diameter 5 mm | |
Operating range *2 | 0.2 to 7 m | |
Response time
(under stable light incident condition) |
ON to OFF | 15 ms max. |
OFF to ON | 70 ms max. | |
Startup waiting time | 2 s max. | |
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | |
Consumption
current (no load) |
PNP output | Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams:
63 mA max. Receiver: Up to 22 beams: 42 mA max., 26 to 42 beams: 47 mA max., 46 to 54 beams: 51 mA max. |
NPN output | Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams:
63 mA max. Receiver: Up to 22 beams: 40 mA max., 26 to 42 beams: 45 mA max., 46 to 54 beams: 48 mA max. |
|
Light source (emitted
wavelength) |
Infrared LED (870 nm) | |
Effective aperture angle
(EAA) |
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the
detection distance is 3 m or over |
|
Safety outputs
(OSSD) |
PNP output | Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
NPN output | Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
|
Output operation mode | Safety output: On when receiving light | |
Input voltage | PNP output | Test input:
ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 |
NPN output | Test input:
ON voltage: 0 to 3 V (short circuit current: approx. 4.0 mA) OFF voltage: 1/2 Vs to Vs or open (short circuit current: approx. 3.0 mA) *5 |
|
Mutual interference
prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | |
Test function | Self test (at power-ON and at power distribution)
External test (emission stop function by test input) |
|
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | |
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | |
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | |
Operating ambient light
intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | |
Degree of protection | IP65 (IEC 60529) | |
Vibration resistance | Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions (no delay at resonant frequencies) |
|
Shock resistance | Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total) |
|
Pollution degree | Pollution degree 3 (IEC 60664-1) | |
Power cable | Connection method: Pull-out type, cable length 3 m
Number of wires: Emitter: 5 wires, receiver: 6 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
|
Extension cable | 30 m max. *6 | |
Material | Case: Aluminum
Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
|
Net Weight *7 | Weight (g) = (protective height) x 1.59 + 330 | |
Gross Weight *8 | Weight (g) = (protective height) x 2.6 + 800 | |
Accessories | Instruction Manual, Quick Installation Manual (QIM) *9 | |
Applicable standards *10 | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective
Equipment) IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. To extend a cable of the F3SJ-E, refer to the User's Manual (SCHG-733/732).
*7. The net weight is the weight of an emitter and a receiver.
*8. The gross weight is the weight of an emitter, a receiver, included accessories and a package.
*9. Mounting brackets and test rod are sold separately.
*10.Refer to Safety Precautions for information about Legislation and Standards.
Nameofindicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is
receiving light. |
--- |
Stable-state
indicator |
STB | Turns ON when incidence level is more
than 170% of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is ON.
Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-E enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-E enters a
lockout on the receiver. |
Blinks when the F3SJ-E enters a lockout
on the emitter. |
Power indicator | POWER | Turns ON while the power of the
emitter is ON. |
Blinks when the F3SJ-E enters a lockout
due to power voltage/noise. |
Test indicator | TEST | --- | Blinks when external test is being
performed. |
Bottom-beam-
state indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
--- |
Nameofindicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
--- |
Stable-state
indicator |
STB | Turns ON when incidence level is more
than 170% of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is ON.
Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-E enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-E enters a
lockout on the emitter. |
Blinks when the F3SJ-E enters a lockout
on the receiver. |
Communication
indicator |
COM | Turns ON when communication between
emitter and receiver is established. |
Blinks when the F3SJ-E enters lockout
due to a communication error between receiver and emitter. |
Configuration
indicator |
CFG | --- | Blinks when the F3SJ-E enters lockout
due to a model type error between receiver and emitter. |
Internal error
indicator |
INTERNAL | --- | Blinks when the F3SJ-E enters a lockout
due to an internal error. |
Bottom-beam-
state indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
--- |
Model | F39-PTJ |
---|---|
Applicable sensor | F3SJ Series |
Power supply voltage | 4.65 or 4.5 VDC |
Battery | Three button batteries (SR44 or LR44) |
Battery life * | SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation |
Light source | Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2,
EN/IEC class 2, FDA class II) |
Spot diameter (typical value) | 6.5 mm at 10 m |
Ambient temperature | Operating: 0 to 40°C, Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Material | Laser module case: aluminum, Mounting bracket: aluminum and stainless |
Weight | Approx. 220 g (packed) |
Accessories | Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3),
instruction manual |
* Battery life varies depending on a battery used.
Model | PNP output | F3SJ-B[][][][]P25 |
---|---|---|
NPN output | F3SJ-B[][][][]N25 | |
Sensor type | Type 4 safety light curtain | |
Setting tool connection *1 | Parameter settings: Not available | |
Safety category | Safety purpose of category 4, 3, 2, 1, or B | |
Detection capability | Opaque objects 25mm in diameter | |
Beam gap (P) | 20 mm | |
Number of beams (n) | 8 to 102 | |
Protective height (PH) | 185 to 2,065 mm | |
Lens diameter | Diameter 5 mm | |
Operating range *2 | 0.2 to 7 m | |
Response time
(under stable light incident condition) |
ON to OFF | 15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) |
OFF to ON | 70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) | |
Startup waiting time | 2 s max. | |
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | |
Consumption
current (no load) |
PNP output | Emitter: Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75
mA max., 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. Receiver: Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA max., 46 to 62 beams: 56 mA max., 66 to 82 beams: 61 mA max., 86 to 102 beams: 67 mA max. |
NPN output | Emitter: Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75
mA max., 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. Receiver: Up to 22 beams: 47 mA max., 26 to 42 beams: 52 mA max., 46 to 62 beams: 58 mA max., 66 to 82 beams: 63 mA max., 86 to 102 beams: 69 mA max. |
|
Light source (emitted
wavelength) |
Infrared LED (870 nm) | |
Effective aperture angle
(EAA) |
Based on IEC 61496-2.Within +/-2.5° for both emitter and receiver when the detection
distance is 3 m or over |
|
Safety outputs
(OSSD) |
PNP output | Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
NPN output | Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
|
Auxiliary
output |
PNP output | One PNP transistor outputs, load current 100 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), leak current 1 mA max. |
NPN output | One NPN transistor outputs, load current 100 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), leak current 1 mA max. |
|
Output operation mode | Safety output: On when receiving light
Auxiliary output: - Reverse output of safety output for a basic system - ON when muting/override for a muting system |
|
Input voltage | PNP output | Test input, Interlock select input, Reset input, Muting input:
ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5, OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 External device monitoring input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.0 mA) *5, OFF voltage: open |
NPN output | Test input, Interlock select input, Reset input, Muting input:
ON voltage: 0 to 3 V (short circuit current: approx. 4.0 mA), OFF voltage:1/2 Vs to Vs or open (short circuit current: approx. 3.0 mA) *5 External device monitoring input: ON voltage: 0 to 3 V (short circuit current: approx. 5.5 mA) *5, OFF voltage: open |
|
Mutual interference
prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | |
Series connection | Time division emission by series connection
• Number of connections: up to 3 sets (between F3SJ-Bs only)Other models cannot be connected. • Total number of beams: up to 192 beams • Cable length between sensors: 7 m max. (not including series connection cable (F39- JBR2W) and power cable) |
|
Test function | • Self test (at power-ON and at power distribution)
• External test (emission stop function by test input) |
|
Safety-related functions | • Interlock (basic system)
• External device monitoring (basic system) • Muting (muting system) • Override (muting system) |
|
Connection type | Connector method (M12, 8-pin) | |
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | |
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | |
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | |
Operating ambient light
intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | |
Degree of protection | IP65 (IEC 60529) | |
Vibration resistance | Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions (no delay at resonant frequencies) |
|
Shock resistance | Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total) |
|
Pollution degree | Pollution degree 3 (IEC 60664-1) | |
Power cable | Connection method: Prewired connector cable, cable length 0.3 m, connector type
(M12, 8-pin), connector: IP67 rated (when mated) Number of wires: 8 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
|
Extension cable | 30 m max. | |
Material | Case: Aluminum
Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
|
Net Weight *6 | Weight (g) = (protective height) x 1.62 + 110 | |
Gross Weight *7 | Weight (g) = (protective height) x 2.7 + 500 | |
Accessories | Instruction Manual, Quick Installation Manual (QIM) *8 | |
Applicable standards *9 | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective
Equipment) IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks during muting/override, or when cap
error or connection error occurs. |
Stable-state
indicator |
STB | Turns ON when incidence level is more
than 170% of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the receiver. |
Blinks when the F3SJ-B enters a lockout
on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter
is ON. |
Blinks when the F3SJ-B enters a lockout
due to power voltage/noise. |
Test indicator | TEST | --- | Blinks when external test is being
performed. |
Muting error
indicator |
MUTING
ERROR |
--- | Blinks during a muting error. |
Muting input 1
indicator |
MUTE1 | Turns ON when muting input 1 is ON
under the muting system. |
--- |
Muting input 2
indicator |
MUTE2 | Turns ON when muting input 2 is ON
under the muting system. |
--- |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
Blinks during muting/override. |
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks during muting/override, or when
cap error or connection error occurs. |
Stable-state indicator | STB | Turns ON when incidence level is more
than 170% of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the emitter. |
Blinks when the F3SJ-B enters a lockout
on the receiver. |
Communication
indicator |
COM | Turns ON when communication between
emitter and receiver is established. |
Blinks when the F3SJ-B enters lockout
due to a communication error between receiver and emitter. |
Configuration
indicator |
CFG | --- | Blinks when the F3SJ-B enters lockout
due to a model type error between receiver and emitter. |
Internal error
indicator |
INTERNAL | --- | Blinks when the F3SJ-B enters a lockout
due to an internal error. |
Interlock indicator | INT
-LK |
Turns ON when the F3SJ-B is in interlock
state. |
Blinks when the F3SJ-B enters a lockout
due to a wiring error. |
External device
monitoring indicator |
EDM | Turns ON when an input is given to
external device monitoring input. *1 *2 |
Blinks when the F3SJ-B enters a lockout
due to an external device monitoring error. |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
Blinks during muting/override. |
Model | F3SJ-B[][][][]P25-01TS | F3SJ-B[][][][]P25-02TS | |
---|---|---|---|
Sensor type | Type 4 safety light curtain | ||
Setting tool connection *1 | Parameter settings: Not available | ||
Safety category | Safety purpose of category 4, 3, 2, 1, or B | ||
Detection capability | Opaque objects 25mm in diameter | ||
Beam gap (P) | 20 mm | ||
Number of beams (n) | 8 to 102 | 10 to 98 | |
Protective height (PH) | 185 to 2,065 mm | 225 to 1,985 mm | |
Lens diameter | Diameter 5 mm | ||
Operating range *2 | 0.2 to 7 m *2 | 0.2 to 6 m | |
Response time
(under stable light incident condition) |
ON to OFF | 15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) | |
OFF to ON | 70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) | ||
Startup waiting time | 2 s max. | ||
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | ||
Consumption
current (no load) |
Emitter | Up to 22 beams: 52 mA max., 26 to 42
beams: 68 mA max., 46 to 62 beams: 75 mA max., 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. |
Up to 22 beams: 52 mA max., 26 to 42
beams: 68 mA max., 46 to 62 beams: 75 mA max., 66 to 82 beams: 88 mA max., 86 to 98 beams: 99 mA max. |
Receiver | Up to 22 beams: 45 mA max., 26 to 42
beams: 50 mA max., 46 to 62 beams: 56 mA max., 66 to 82 beams: 61 mA max., 86 to 102 beams: 67 mA max. |
Up to 22 beams: 45 mA max., 26 to 42
beams: 50 mA max., 46 to 62 beams: 56 mA max., 66 to 82 beams: 61 mA max., 86 to 98 beams: 66 mA max. |
|
Light source (emitted
wavelength) |
Infrared LED (870 nm) | ||
Effective aperture angle
(EAA) |
Based on IEC 61496-2.Within +/-2.5° for both emitter and receiver when the
detection distance is 3 m or over |
||
Safety outputs (OSSD) | Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
||
Auxiliary output | One PNP transistor outputs, load current 100 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), leak current 1 mA max. |
||
Output operation mode | Safety output: On when receiving light
Auxiliary output: Reverse output of safety output |
Safety output: On when receiving light
Auxiliary output: • Basic system Reverse output of safety output • Muting system On during muting/override |
|
Input voltage | Test input
ON voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 OFF voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 Reset input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 External device monitoring input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.0 mA) *5 OFF voltage: open |
Test input, Interlock select input, Reset
input, Muting input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 External device monitoring input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.0 mA) *5 OFF voltage: open |
|
Mutual interference
prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | ||
Series connection | Time division emission by series
connection • Number of connections: up to 3 sets (between F3SJ-B[][][][]P25-01TSs only) Other models cannot be connected. • Total number of beams: up to 192 beams • Cable length between sensors: 7 m max. (not including series connection cable (F39-JBR2W) and power cable) |
Time division emission by series
connection • Number of connections: up to 3 sets (between F3SJ-B[][][][] P25-02TSs only) Other models cannot be connected. • Total number of beams: up to 192 beams • Cable length between sensors: 7 m max. (not including series connection cable (F39-JBR2W) and power cable) |
|
Test function | • Self test (at power-ON and at power distribution)
• External test (emission stop function by test input) |
||
Safety-related functions | External device monitoring | External device monitoring (basic system)
Muting (muting system) Override (muting system) |
|
Connection type | Connector method (M12, 8-pin) | ||
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | ||
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | ||
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | ||
Operating ambient light
intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | ||
Degree of protection | IP65 (IEC 60529) | ||
Vibration resistance | Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions (no delay at resonant frequencies) |
||
Shock resistance | Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total) |
||
Pollution degree | Pollution degree 3 (IEC 60664-1) | ||
Power cable | Connection method: Prewired connector cable, cable length 0.3 m, connector type (M12,
8-pin), connector: IP67 rated (when mated) Number of wires: 8 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
||
Extension cable | 30 m max. | ||
Material | Case: Aluminum
Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
||
Net Weight *6 | Weight (g) = (protective height) x 1.62 +
110 |
Weight (g) = (protective height) x 1.83 +
122 |
|
Gross Weight *7 | Weight (g) = (protective height) x 2.7 + 500 | Weight (g) = (protective height) x 2.9 + 550 | |
Accessories | Quick Installation Manual (QIM), Instruction Manual *8 | ||
Applicable standards *9 | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective
Equipment) IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks when cap error or connection error
occurs. |
Stable-state
indicator |
STB | Turns ON when incidence level is 170% or
more of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the receiver. |
Blinks when the F3SJ-B enters a lockout
on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter
is ON. |
Blinks when the F3SJ-B enters a lockout
due to power voltage/noise. |
Test indicator | TEST | --- | Blinks when external test is being
performed. |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
--- |
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks when cap error or connection error
occurs. |
Stable-state indicator | STB | Turns ON when incidence level is 170%
or more of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the emitter. |
Blinks when the F3SJ-B enters a lockout
on the receiver. |
Communication
indicator |
COM | Turns ON when communication between
emitter and receiver is established. |
Blinks when the F3SJ-B enters lockout
due to a communication error between receiver and emitter. |
Configuration
indicator |
CFG | --- | Blinks when the F3SJ-B enters lockout
due to a model type error between receiver and emitter. |
Internal error
indicator |
INTERNAL | --- | Blinks when the F3SJ-B enters a lockout
due to an internal error. |
Interlock indicator | INT
-LK |
Not used | Not used |
External device
monitoring indicator |
EDM | Turns ON when an input is given to
external device monitoring input. * |
Blinks when the F3SJ-B enters a lockout
due to an external device monitoring error. |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
--- |
* It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks during muting/override, or when
cap error or connection error occurs. |
Stable-state indicator | STB | Turns ON when incidence level is 170%
or more of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the receiver. |
Blinks when the F3SJ-B enters a lockout
on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter
is ON. |
Blinks when the F3SJ-B enters a lockout
due to power voltage/noise. |
Test indicator | TEST | --- | Blinks when external test is being
performed. |
Muting error indicator | MUTING
ERROR |
--- | Blinks during a muting error. |
Muting input 1
indicator |
MUTE1 | Turns ON when muting input 1 is ON
under the muting system. |
--- |
Muting input 2
indicator |
MUTE2 | Turns ON when muting input 2 is ON
under the muting system. |
--- |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
Blinks during muting/override. |
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks during muting/override, or when
cap error or connection error occurs. |
Stable-state indicator | STB | Turns ON when incidence level is 170%
or more of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the emitter. |
Blinks when the F3SJ-B enters a lockout
on the receiver. |
Communication
indicator |
COM | Turns ON when communication between
emitter and receiver is established. |
Blinks when the F3SJ-B enters lockout
due to a communication error between receiver and emitter. |
Configuration
indicator |
CFG | --- | Blinks when the F3SJ-B enters lockout
due to a model type error between receiver and emitter. |
Internal error
indicator |
INTERNAL | --- | Blinks when the F3SJ-B enters a lockout
due to an internal error. |
Interlock indicator | INT
-LK |
Not used | Not used |
External device
monitoring indicator |
EDM | Turns ON when an input is given to
external device monitoring input. * |
Blinks when the F3SJ-B enters a lockout
due to an external device monitoring error. |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
Blinks during muting/override. |
* It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
Model | F3SP-B1P | |
---|---|---|
Applicable sensor | F3SJ-B/A (Only for PNP output type) * | |
Power supply voltage | 24 VDC±10% | |
Power consumption | DC1.7 W max. (not including sensor's current consumption) | |
Operation time | 100 ms max. (not including sensor's response time) | |
Response time | 100 ms max. (not including sensor's response time) | |
Relay output | Number of contacts | 3NO+1NC |
Rated load | 25 VAC 5 A (cos ϕ = 1), 30 VDC 5 A L/R = 0 ms | |
Rated current | 5 A | |
Connection type | Between sensors | M12 connector (8-pin) |
Others | Terminal block | |
Weight (packed state) | Approx. 280 g | |
Accessories | Instruction manual |
* NPN output type cannot be connected. Also, the system cannot be used as a muting system.
Model | F39-PTJ |
---|---|
Applicable sensor | F3SJ Series *1 |
Power supply voltage | 4.65 or 4.5 VDC |
Battery | Three button batteries (SR44 or LR44) |
Battery life *2 | SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation |
Light source | Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2,
EN/IEC class 2, FDA class II) |
Spot diameter (typical value) | 6.5 mm at 10 m |
Ambient temperature | Operating: 0 to 40°C Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Material | Laser module case: aluminum Mounting bracket: aluminum and stainless |
Weight | Approx. 220 g (packed) |
Accessories | Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3),
instruction manual |
*1. It cannot be mounted to the models with the suffix "-02TS".
*2. Battery life varies depending on a battery used.
Model | PNP
outputs |
F3SJ-A[][][][]P14 | F3SJ-A[][][][]P20 | F3SJ-A[][][][]P30 | F3SJ-A[][][][]P55 |
---|---|---|---|---|---|
NPN
outputs |
F3SJ-A[][][][]N14 | F3SJ-A[][][][]N20 | F3SJ-A[][][][]N30 | F3SJ-A[][][][]N55 | |
Sensor type | Type 4 safety light curtain | ||||
Version | Ver. 2 | ||||
Setting tool connection | Connectable | ||||
Safety category | Safety purpose of category 4, 3, 2, 1, or B | ||||
Detection capability | Opaque objects
14 mm in diameter |
Opaque objects
20 mm in diameter |
Opaque objects
30 mm in diameter |
Opaque objects
55 mm in diameter |
|
Beam gap (P) | 9 mm | 15 mm | 25 mm | 50 mm | |
Number of beams (n) | 26 to 140 | 16 to 100 | 10 to 100 | 6 to 50 | |
Protective height (PH) | 245 to 1,271 mm | 245 to 1,505 mm | 245 to 2,495 mm | 270 to 2,470 mm | |
Lens diameter | Diameter 5 mm | ||||
Operating range * | 0.2 to 9 m (protective height 1,640 mm max.), 0.2 to 7 m (protective height 1,655 mm min.)
(Depending on the setting tool, the detection distance can be shortened to 0.5 m.) |
||||
Response
time (under stable light incident condition) (For details, see "Response Time" on Catalog.) |
ON to OFF | 1 set,
0245 to 983: 11 ms to 17.5 ms max. 1,055 or higher: 20 ms to 25 ms max. |
1 set,
0245 to 1205: 10 ms to 15 ms max. 1235 or higher: 17.5 ms to 22.5 ms max. |
1 set: 10 ms to
17.5 ms max. |
1 set: 10 ms to
13 ms max. |
OFF to ON | 1 set,
0245 to 983: 44 ms to 70 ms max. 1,055 or higher: 80 ms to 100 ms max. |
1 set,
0245 to 1205: 40 ms to 60 ms max. 1235 or higher: 70 ms to 90 ms max. |
1 set: 40 ms to
70 ms max. |
1 set: 40 ms to
52 ms max. |
|
Startup waiting time | 2 s max. (2.2 s max. for series connection) | ||||
Power supply voltage (Vs) | 24 VDC ±20% (ripple p-p10% max.) | ||||
Current
consumption (no load) |
Emitter | To 50 beams: 76 mA max., 51 to 100 beams: 106 mA max., 101 to 150 beams: 130 mA
max., 151 to 180 beams: 153 mA max., 201 to 234 beams: 165 mA max. |
|||
Receiver | To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA
max., 151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max. |
||||
Light source (emitted
wavelength) |
Infrared LED (870 nm) | ||||
Effective aperture angle
(EAA) |
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the detection
distance is 3 m or over |
||||
Safety
outputs (OSSD) |
PNP
outputs |
Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), allowable capacity load 2.2 μF, leak current 1 mA max. (This can be different from traditional logic (ON/OFF) because safety circuit is used.) |
|||
NPN
Output |
Two NPN transistor outputs, load current 300 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), allowable capacity load 2.2 μF, leak current 2 mA max. (This can be different from traditional logic (ON/OFF) because safety circuit is used.) |
||||
Auxiliary
output 1 (Non-safety output) |
PNP
outputs |
One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), leak current 1 mA max. |
|||
NPN
Output |
One NPN transistor output, load current 300 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), leak current 1 mA max. |
||||
Auxiliary
output 2 (Non-safety output. Function for Basic System.) |
PNP
outputs |
One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), leak current 1 mA max. |
|||
NPN
Output |
One NPN transistor output, load current 50 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), leak current 1 mA max. |
||||
External indicator output
(Non-safety output) |
Available indicators
• Incandescent lamp: 24 VDC, 3 to 7 W • LED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max. (To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.) |
||||
Output
operation mode |
Receiver | Safety output 1, 2: ON when receiving light
Auxiliary output 1: Inverse of safety output signals (Operation mode can be changed with the setting tool.) External indicator output 1: Inverse of safety output signals for a basic system (Operation mode can be changed with the setting tool.), ON when muting/override for a muting system (Operation mode can be changed with the setting tool.) |
|||
Emitter | Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached
(Operation mode can be changed with the setting tool.) External indicator output 2: ON when lock-out for a basic system (Operation mode can be changed with the setting tool.) ON when muting/override for a muting system (Operation mode can be changed with the setting tool.) |
||||
Input
voltage |
PNP
output |
Test input, Interlock select input, Reset input, Muting input:
ON voltage: 9 V to Vs (short circuit current: approx. 2.0 mA), OFF voltage: 0 to 1.5 V, or open External device monitoring input: ON voltage: 9 V to Vs (short circuit current: approx. 3.5 mA), OFF voltage:open Note: The Vs indicates a voltage value in your environment. |
|||
NPN
output |
Test input, Interlock select input, Reset input, Muting input:
ON voltage: 0 to 1.5 V (short-circuit current: approx. 1.5 mA), OFF voltage: 9 V to Vs, or open External device monitoring input: ON voltage: 0 to 1.5 V (short-circuit current: approx. 4.0 mA), OFF voltage:open Note: The Vs indicates a voltage value in your environment. |
||||
Indicator | Emitter | Light intensity level indicators (green LED x 2, orange LED x 3): ON based on the light
intensity Error mode indicators (red LED x 3): Blink to indicate error details Power indicator (green LED x 1): ON while power is on Interlock indicator (yellow LED x 1): ON while under interlock, blinks at lockout. External device monitoring indicator (muting input 1 indicator), Blanking/test indicator (muting input 2 indicator) (green LED x 2): ON/flash according to function |
|||
Receiver | Light intensity level indicators (green LED x 2, orange LED x 3): ON based on the light
intensity Error mode indicators (red LED x 3): Blink to indicate error details OFF output indicator (red LED x 1): ON when safety output is OFF, blinks at lockout. ON output indicator (green LED x 1): ON while safety output is ON Muting error indicator, Blanking /test indicator (green LED x 2): ON/flash according to function |
||||
Mutual interference
prevention function |
Interference light prevention algorithm, detection distance change function | ||||
Series connection | Time division emission by series connection
• Number of connections: up to 4 sets (F3SJ-A only) F3SJ-E, F3SJ-B and F3SJ-TS cannot be connected. • Total number of beams: up to 400 beams • Cable length between sensors: 15 m max. (not including series connection cable (F39-JJR3W or F39-JJR[]L) and power cable) • Response time under connection: Refer to Catalog |
||||
Test function | • Self test (at power-ON and at power distribution)
• External test (emission stop function by test input) |
||||
Safety-related functions | • Start interlock, restart interlock (Must be set with a setting tool when the muting function is used.)
• External device monitor • Muting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.) • Fixed blanking (must be set by a setting tool) • Floating blanking (must be set by a setting tool) |
||||
Connection method | Connector method (M12, 8-pin) | ||||
Protective circuits | Output short-circuit protection, and power supply reverse polarity protection | ||||
Ambient temperature | Operating: -10 to 55°C (no icing), Storage: -30 to 70°C | ||||
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% | ||||
Operating ambient light
intensity |
Incandescent lamp: receiving-surface light intensity of 3,000 lx max., Sunlight: receiving-
surface light intensity of 10,000 lx max. |
||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Withstand voltage | 1,000 VAC 50/60 Hz, 1 min | ||||
Degree of protection | IP65 (IEC 60529) | ||||
Vibration resistance | Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions (no delay at resonant frequencies) |
||||
Shock resistance | Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total) |
||||
Materials | Casing (including metal parts on both ends): Aluminum, zinc die-cast
Cap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC |
||||
Net Weight *1 | Calculate using the following expressions:
(1) For F3SJ-A[][][][][]14, weight (g) = (protective height) x 1.67 + 215 (2) For F3SJ-A[][][][][]20, weight (g) = (protective height) x 1.5 + 217 (3) For F3SJ-A[][][][][]30, weight (g) = (protective height) x 1.41 + 220 (4) For F3SJ-A[][][][][]55, weight (g) = (protective height) x 1.3 + 220 |
||||
Gross Weight *1 | Calculate using the following expressions:
(1) For F3SJ-A[][][][][]14, weight (g) = (protective height) x 1.7 + α (2) For F3SJ-A[][][][][]20/F3SJ-A[][][][][]30, weight (g) = (protective height) x 1.5 + α (3) For F3SJ-A[][][][][]55, weight (g) = (protective height) x 1.4 + α The values for α are as follows: Protected height 245 to 596 mm: = 1,100 protected height 1,660 to 2,180 mm: = 2,400 Protected height 600 to 1,130 mm: = 1,500 protected height 2,195 to 2,500 mm: = 2,600 Protected height 1,136 to 1,658 mm: = 2,000 |
||||
Accessories | Instruction manual, standard mounting bracket (F39-LJ1 bracket for top/bottom
mounting), mounting brackets (intermediate) (*), error mode label, Quick Installation Manual (QIM) *. Number of intermediate brackets depends on protective height of F3SJ. • For protective height from 600 to 1,130 mm: 1 set for each of the emitter and receiver is included • For protective height from 1,136 to 1,658 mm: 2 sets for each of the emitter and receiver are included • For protective height from 1,660 to 2,180 mm: 3 sets for each of the emitter and receiver are included • For protective height from 2,195 to 2,500 mm: 4 sets for each of the emitter and receiver are included |
||||
Applicable standards *3 | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective
Equipment) IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
* Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*1. The net weight is the weight of an emitter and a receiver.
*2. The gross weight is the weight of an emitter, a receiver, included accessories and a package.
*3. Refer to Safety Precautions for information about Legislation and Standards.
Model | Protected Height
(mm) |
Number of Beams | Response time ms
(ON to OFF) |
Response time ms
(OFF to ON) |
---|---|---|---|---|
F3SJ-A[]14 Series | 245 to 263 | 26 to 28 | 11 | 44 |
281 to 389 | 30 to 42 | 12 | 48 | |
407 to 497 | 44 to 54 | 13 | 52 | |
515 to 605 | 56 to 66 | 14 | 56 | |
623 to 731 | 68 to 80 | 15 | 60 | |
767 to 983 | 84 to 108 | 17.5 | 70 | |
1,055 to 1,271 | 116 to 140 | 20 | 80 | |
F3SJ-A[]20 Series | 245 | 16 | 10 | 40 |
275 to 425 | 18 to 28 | 11 | 44 | |
455 to 635 | 30 to 42 | 12 | 48 | |
665 to 815 | 44 to 54 | 13 | 52 | |
845 to 995 | 56 to 66 | 14 | 56 | |
1,025 to 1,205 | 68 to 80 | 15 | 60 | |
1,235 to 1,505 | 82 to 100 | 17.5 | 70 | |
F3SJ-A[]30 Series | 245 to 395 | 10 to 16 | 10 | 40 |
420 to 720 | 17 to 29 | 11 | 44 | |
745 to 1,045 | 30 to 42 | 12 | 48 | |
1,070 to 1,295 | 43 to 52 | 13 | 52 | |
1,395 to 1,620 | 56 to 65 | 14 | 56 | |
1,745 to 1,995 | 70 to 80 | 15 | 60 | |
2,120 to 2,495 | 85 to 100 | 17.5 | 70 | |
F3SJ-A[]55 Series | 270 to 770 | 6 to 16 | 10 | 40 |
820 to 1,420 | 17 to 29 | 11 | 44 | |
1,470 to 2,070 | 30 to 42 | 12 | 48 | |
2,120 to 2,470 | 43 to 50 | 13 | 52 |
Total cable extension length must be no greater than the lengths described below.
Condition | 1 set | 2 sets | 3 sets | 4 sets |
---|---|---|---|---|
Using incandescent lamp for auxiliary output and external indicator output | 45 m | 40 m | 30 m | 20 m |
Not using incandescent lamp * | 100 m | 60 m | 45 m | 30 m |
Condition | 1 set | 2 sets | 3 sets | 4 sets |
---|---|---|---|---|
Using incandescent lamp for external indicator output 2 | 40 m | 30 m | 25 m | 20 m |
Using incandescent lamp for external indicator output 1 | 60 m | 45 m | 30 m | 20 m |
Using incandescent lamp for auxiliary output 1 | ||||
Not using incandescent lamp * | 100 m | 60 m | 45 m | 30 m |
Model | F3SP-B1P | |
---|---|---|
Applicable sensor | F3SJ-B/A (Only for PNP output type) * | |
Power supply voltage | 24 VDC±10% | |
Power consumption | DC1.7 W max. (not including sensor's current consumption) | |
Operation time | 100 ms max. (not including sensor's response time) | |
Response time | 10 ms max. (not including sensor's response time) | |
Relay output | Number of contacts | 3NO+1NC |
Rated load | 25 VAC 5 A (cos ϕ = 1), 30 VDC 5 A L/R = 0 ms | |
Rated current | 5 A | |
Connection type | Between sensors | M12 connector (8-pin) |
Others | Terminal block | |
Weight (packed state) | Approx. 280 g | |
Accessories | Instruction manual |
* NPN output type cannot be connected. Also, the system cannot be used as a muting system.
Model | F39-PTJ |
---|---|
Applicable sensor | F3SJ Series |
Power supply voltage | 4.65 or 4.5 VDC |
Battery | Three button batteries (SR44 or LR44) |
Battery life * | SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation |
Light source | Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2,
EN/IEC class 2, FDA class II) |
Spot diameter (typical value) | 6.5 mm at 10 m |
Ambient temperature | Operating: 0 to 40°C Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Material | Laser module case: aluminum Mounting bracket: aluminum and stainless |
Weight | Approx. 220 g (packed) |
Accessories | Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3),
instruction manual |
* Battery life varies depending on a battery used.
Model | F39-A01PR-PAC | F39-A01PG-PAC | F39-A01PY-PAC |
---|---|---|---|
Applicable sensor | F3SJ-A (Common for PNP/NPN output type. Can be attached to emitters and/or receivers) | ||
Light source | Red LED | Green LED | Yellow LED |
Power supply voltage | 24 VDC±10% (supplied by sensor) | ||
Consumption current | 50 mA max. (supplied by sensor) | ||
Connection type | Dedicated accessory connector cable (Sensor side: Dedicated 10-pin connector,
Indicator side: M12 8-pin connector) |
||
Set details | Indicator (red),
Dedicated connector cable (0.1 m), Dedicated mounting bracket (1 for each) |
Indicator (green),
Dedicated connector cable (0.1 m), Dedicated mounting bracket (1 for each) |
Indicator (yellow),
Dedicated connector cable (0.1 m), Dedicated mounting bracket (1 for each) |
Model | F39-EJ[][][][]-L, F39-EJ[][][][]-D | |
---|---|---|
Applicable sensor | F3SJ-A Series Curtains with a protective
height of 600 mm or shorter. |
F3SJ-A Series Curtains with a protective
height of 605 mm or longer. |
Ambient temperature | -10 to 55°C (operation and storage) | 13 to 33°C (operation and storage) |
Mounting direction | No restrictions | Vertical direction only (see following diagram) |
Operating range | 0.2 to 7 m (for a protective height of 1,631 mm max.), 0.2 to 5 m (for a protective height
of 1,655 mm min.) |
|
Degree of protection | IP67 (IEC 60529) (When assembled according to the application precautions) | |
Material | Case: Acrylic resin, Rubber: Nitrile rubber, M5 bolt: SUSXM7, M4 bolt: SUS316L,
Cable: Oil-resistant PVC, Plate: SUS304, Mounting Bracket (optional): SUS304 |
|
Weight (packed state) | Calculation formula: Weight (g) = 1.5 x [][][][] + 300 ([][][][] stands for the four digits of the
model number (protective height)) (The optional Mounting Brackets come in a set of two, and weigh 120 g. This weight is not included in the above formula.) |
last update: September 11, 2023