Connector-Terminal Block Conversion Units for General-purpose Devices
last update: April 1, 2015
Rated current | Power supply terminal block: 2 A,
Connectors/e-CON Connectors: 1 A (However, rated current of e-CON Connector depends on the wires that are used.) |
|
---|---|---|
Rated voltage | 24VDC | |
Insuration resistance | 100MΩ min. (at 500VDC) | |
Dielectric strength | 500VAC for 1 min (leakage current: 1 mA max.) | |
Ambient operating temperature | 0 to 55°C | |
Applicable
wires |
Applicable wire
sizes * |
AWG 24 to 14 (ferrules),
AWG 28 to 14 (stranded wires), AWG 28 to 16 (solid wires) (Outer diameter of insulation must be 4 mm max) |
Stripped length | AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm |
Rated current | 3 A/pin (with AWG20 wires), 2 A/pin (with AWG22 wires),
1 A/pin (with AWG24 wires), 0.5 A/pin (with AWG26 or AWG28 wires) |
---|---|
Rated voltage | 32 VDC |
Contact resistance | 30 mΩ max. (at 20 mV, 100 mA max.) |
Insuration resistance | 103 MΩ min. (at 500VDC) |
Dielectric strength | 1,000 VAC for 60 sec (leakage current: 1 mA max.) |
Insertion durability | 50 times |
Ambient operating temperature | -30 to 75°C * |
Applicable wires | Stranded wire 0.08mm2 (AWG28) to 0.5mm2 (AWG20)
(Outer diameter of insulation must be 1.5 mm max) |
* The operating temperature range is restricted by the maximum operating temperature of the cable.
Rated current | 1 A | |
---|---|---|
Rated voltage | 125 VAC, 24 VDC | |
Insuration resistance | 100 MΩ min. (at 500 VDC) | |
Dielectric strength | 500 VAC for 1 min (leakage current: 1 mA max.) | |
Ambient operating temperature | 0 to 55°C | |
Applicable wires | Applicable wire sizes | AWG 22 to 16 (round or forked crimp terminals)
AWG 26 to 16 (stranded or solid wires) |
Stripped length | 9 mm | |
Tightening | 0.5 Nm |
Rated current | 1 A | |
---|---|---|
Rated voltage | 125 VAC, 24 VDC | |
Insuration resistance | 100 MΩ min. (at 500 VDC) | |
Dielectric strength | 500 VAC for 1 min (leakage current: 1 mA max.) | |
Ambient operating temperature | 0 to 55°C | |
Applicable wires | Applicable wire sizes | AWG 22 to 16 (ferrules)
AWG 26 to 16 (stranded or solid wires) |
Stripped length | 7 mm | |
Tightening | 0.5 to 0.6 N·m |
Rated current | 1 A | |
---|---|---|
Rated voltage | 125 VAC, 24 VDC | |
Insuration resistance | 100 MΩ min. (at 500 VDC) | |
Dielectric strength | 500 VAC for 1 min (leakage current: 1 mA max.) | |
Ambient operating temperature | 0 to 55°C | |
Applicable wires | Applicable wire sizes | AWG 24 to 14 (ferrules)
AWG 28 to 14 (stranded or solid) (Outer diameter of insulation must be 4 mm max) |
Stripped length | AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm |
last update: April 1, 2015