Page top

Industrial Automation

Industrial Automation

ZN-PD-S

Air Particle Sensor

ZN-PD-S

Dust fallout and airborne particles detract from product quality. Continuously monitor these two factors to minimize their effects.

Sensor

Appearance Item (Measured particle diameter) Model
2067_lu_1_1 Air Particle Sensor
Particle measurement type
0.3, 0.5, or 1.0 μm min.
ZN-PD03-SA
ZN-PD03C-SA *1
ZN-PD03F-SA *1 *2
2067_lu_1_2 Air Particle Sensor
Dust measurement type
5 μm (10 μm), 20 μm (30 μm), 50 μm min.
ZN-PD50-SA
ZN-PD50C-SA *1
2067_lu_1_3 Air Thermo Sensor
For temperature/humidity measurement
ZN-TH11-S
ZN-TH11C-S∗1

Please choose this form when you buy with the calibration certificate.
*1 Contents of Certificate of Calibration Set: Calibration Certificate, Inspection Result (ZN-PD03C-SA: 0.3 μm inspection
     data, ZN-PD50C-SA: 5 μm inspection data), and Traceability Chart
*2 For the ZN-PD03F-SA, both 0.3 μm and 0.5 μm inspection data will be given in the Inspection Results.

Accessories (Order separately)

Shape Item (Applicable Standards) Rated Voltage Model
2067_lu_2_1
AC adaptor (PSE) 100 to 125 VAC ZN9-ACP02-PSE
2067_lu_2_2
AC adaptor (CCC) 100 to 240 VAC ZN9-ACP02-CCC
2067_lu_2_3
AC adaptor (KC) 100 to 240 VAC ZN9-ACP02-KC
2067_lu_2_4
AC adaptor (CE) 100 to 240 VAC ZN9-ACP02-CE
2067_lu_2_5
AC adaptor (UL) 100 to 125 VAC ZN9-ACP02-UL

Appearance Item Model
2067_lu_3_1 Change filter set for Particle measurement type ZN9-PF1-S
2067_lu_3_2 Change filter set for Dust measurement type ZN9-PF2-S
2067_lu_3_3 Change funnel for Dust measurement type ZN9-PG1-S
2067_lu_3_4 Exhaust tube (4 m) ZN9-PT4-S
Exhaust tube (8 m) ZN9-PT8-S
2067_lu_3_5 Filter for cleaning ZN9-PC1-S
2067_lu_3_6 DC cable (2 m)
(ZN9-ED02-S comes with ZN-PD[][]-SA)
Straight type ZN9-ED01-S
Right angle type ZN9-ED02-S

Appearance Item Model
2067_lu_4_1
Connection cable for air particle sensor
(With RJ-45 connectors at both ends, length: 0.1 m)
ZN9-TL01-S
Connection cable for air particle sensor
(With RJ-45 connectors at both ends, length: 2 m)
ZN9-TL20-S
2067_lu_4_2
Connection cable for external device
(With a RJ-45 connector at one end, length: 2 m)
ZN9-TC20-S

PC Software

Appearance Item Model
2067_lu_5_1
Wave Inspire ES ZN-SW11-S

* System requirements OS: Microsoft Windows 7 (32 bit/64 bit)/Microsoft Windows 10 (32 bit/64 bit)
   CPU: compatible Intel processors, 1 GHz or higher.
   Memory: 1 GB or more (2 GB or more recommended)
   The maximum number of connectable sensors is 95.
   (When one PC is connected with a leased line network . The sampling period is set to 10 minutes.)
   The number of possible sensor connections changes by a sampling period, connected number of PC or PLC, and the
   network load situation.

Calibration service

Subject to calibration Content Model
Air Particle Sensor
Particle measurement type
Calibration Certificate, Inspection Result (0.3 μm inspection data),
Traceability chart
ZN9-PD03C-S
Calibration Certificate, Inspection Results (0.3 μm and 0.5 μm
inspection data), and Traceability Chart
ZN9-PD03F-S
Air Particle Sensor
Dust measurement type
Calibration Certificate, Inspection Result,
Traceability chart
ZN9-PD50C-S
Air Thermo Sensor Calibration Certificate, Inspection Result,
Traceability chart
ZN9-TH11C-S

If a Certificate of Calibration is required after you purchase the sensor head, use the above model number to order one.
It is necessary to ship the product back to OMRON in Japan.
* When a ZN-PD[][]-S-series particle sensor is received for the calibration service, parts with a limited service life will be
  replaced and adjusted before the sensor is returned.
  However, it may be determined that the sensor is not repairable due to internal contamination, board corrosion, or other
  reasons. If inspection shows that the sensor is not repairable, only a certificate for the inspection results will be issued.
  (The same fee as for repairs will apply.)