Air Particle Sensor
last update: August 3, 2016
Airborne particles and dust fallout are not correlated due to differences in their behavior.
Therefore, it is necessary to measure both of them separately and accurately.
Putting the particle type on the wall of the room, and the dust type in the vicinity of product processing equipment, is recommended.
Funnel-shaped intake and powerful suction fan efficiently capture falling dust. Large diameter dust is trapped by a built-in filter. Moreover, trapped dust can be collected using two-sided tape attached inside of the pull-out trap box. The dust can then be analyzed under microscope to identify the source.
* The larger the size, the more dust it traps.
Some types of dust may penetrate the trap box.
The Sensor is small enough to fit in the palm of your hand, which makes it easy to mount on a wall or other convenient locations. Maintenance costs are also reduced because the product does not use an external pump that would normally require frequent replacement.
Inputs and outputs include trigger input, alarm output x 2, and error output, which can be used for a variety of purposes including dust level setting, alarm output, timed measurement, and so forth.
Triggers can be input to initiate monitoring when necessary and alarms can be output at desired control levels.
Temperature, humidity and simple dew point can be easily displayed when connected to an Air Particle Sensor*. And, the unit delivers the highest class of sensing performance. You will benefit from wide measurement ranges and highly accurate humidity measuring.
last update: August 3, 2016