DC 2-Wire (PUR Cable/Self-diagnosis Output), AC 2-Wire and AC/DC 2-Wire
E2E-series DC 2-Wire and 3-Wire Models (2E-X[]D[], E2E-X[]E[], E2E-X[]F[]) have been integrated into the E2E NEXT Series. Refer to the catalog (Cat. No. D120) for details.
last update: October 11, 2022
Size | M8 | M12 | ||
---|---|---|---|---|
Shielded | Shielded | Shielded | Unshielded | |
Model | E2E-X2D[] | E2E-X3D[] | E2E-X8MD[] | |
Sensing distance | 2 mm ±10% | 3 mm ±10% | 8 mm ±10% | |
Set distance *1 | 0 to 1.6 mm | 0 to 2.4 mm | 0 to 6.4 mm | |
Differential travel | 15% max. of sensing distance | 10% max. of sensing distance | ||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
|||
Standard sensing object | Iron,
8 × 8 × 1 mm |
Iron,
12 × 12 × 1 mm |
Iron,
30 × 30 × 1 mm |
|
Response frequency *2 | 1.5 kHz | 0.8 kHz | ||
Power supply voltage
(operating voltage range) |
12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC) | |||
Leakage current | 0.8 mA max. | |||
Control
output |
Load current | 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models | ||
Residual
voltage |
3 V max. (Load current: 100 mA, Cable length: 2 m) | |||
Indicators | D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red) |
|||
Operation mode
(with sensing object approaching) |
D1 Models: NO
D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
|||
Diagnostic output delay | 0.3 to 1 s | |||
Protection circuits | Surge suppressor, Load short-circuit protection (for control and diagnostic output) | |||
Ambient temperature
range |
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | |||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±15% max. of sensing distance at 23°C
in the temperature range of -25 to 70°C |
±10% max. of sensing distance at 23°C in
the temperature range of -25 to 70°C |
||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
|||
Shock resistance | Destruction: 500 m/s2 10 times each in X,
Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X,
Y, and Z directions |
||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67 |
|||
Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired
Connector Models (Standard cable length: 0.3 m) |
|||
Weight
(packed state) |
Pre-wired
Models |
Approx. 60 g | Approx. 70 g | |
Pre-wired
Connector Models |
--- | Approx. 40 g
(Shielded Models only) |
||
Connector
Models |
Approx. 15 g | Approx. 25 g | ||
Materi-
als |
Case | Stainless steel (SUS303) | Nickel-plated brass | |
Sensing surface | PBT | |||
Clamping nuts | Nickel-plated brass | |||
Toothed washer | Zinc-plated iron | |||
Accessories | Instruction manual |
Size | M18 | M30 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X7D[] | E2E-X14MD[] | E2E-X10D[] | E2E-X20MD[] | |
Sensing distance | 7 mm ±10% | 14 mm ±10% | 10 mm ±10% | 20 mm ±10% | |
Set distance *1 | 0 to 5.6 mm | 0 to 11.2 mm | 0 to 8 mm | 0 to 16 mm | |
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron,
18 × 18 × 1 mm |
Iron, 30 × 30 × 1 mm | Iron,
54 × 54 × 1 mm |
||
Response frequency *2 | 0.5 kHz | 0.4 kHz | 0.1 kHz | ||
Power supply voltage
(operating voltage range) |
12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC) | ||||
Leakage current | 0.8 mA max. | ||||
Control
output |
Load current | 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models | |||
Residual
voltage |
3 V max. (Load current: 100 mA, Cable length: 2 m) | ||||
Indicators | D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red) |
||||
Operation mode
(with sensing object approaching) |
D1 Models: NO
D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Diagnostic output delay | 0.3 to 1 s | ||||
Protection circuits | Surge suppressor, Load short-circuit protection (for control and diagnostic output) | ||||
Ambient temperature
range |
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
||||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired
Connector Models (Standard cable length: 0.3 m) |
||||
Weight
(packed state) |
Pre-wired
Models |
Approx. 130 g | Approx. 175 g | ||
Pre-wired
Connector Models |
--- | --- | |||
Connector
Models |
Approx. 40 g | Approx. 90 g | |||
Materi-
als |
Case | Nickel-plated brass | |||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object,
and a set distance of half the sensing distance.
Size | M8 | M12 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X1R5Y[] | E2E-X2MY[] | E2E-X2Y[] | E2E-X5MY[] | |
Sensing distance | 1.5 mm ±10% | 2 mm ±10% | 5 mm ±10% | ||
Set distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 4 mm | ||
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron,
8 × 8 × 1 mm |
Iron, 12 × 12 × 1 mm | Iron,
15 × 15 × 1 mm |
||
Response frequency | 25 Hz | ||||
Power supply voltage
(operating voltage range) *1 |
24 to 240 VAC (20 to 264 VAC), 50/60 Hz | ||||
Leakage current | 1.7 mA max. | ||||
Control
output |
Load current *2 | 5 to 100 mA | 5 to 200 mA | ||
Residual voltage | Refer to Engineering Data on Data Sheet. | ||||
Indicators | Operation indicator (red) | ||||
Operation mode
(with sensing object approaching) |
Y1 Models: NO
Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Protection circuits | Surge suppressor | ||||
Ambient temperature range
*1 *2 |
Operating/Storage: -25 to 70°C
(with no icing or condensation) |
Operating/Storage: -40 to 85°C
(with no icing or condensation) |
|||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±10% max. of sensing distance at 23°C
in the temperature range of -25 to 70°C |
±15% max. of sensing distance at 23°C
in the temperature range of -40 to 85°C, ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
|||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying
parts and case |
||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
||||
Shock resistance | Destruction: 500 m/s2 10 times each in
X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each
in X, Y, and Z directions |
|||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | ||||
Weight
(packed state) |
Pre-wired Models
Model |
Approx. 60 g | Approx. 70 g | ||
Connector Models | Approx. 15 g | Approx. 25 g | |||
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
Size | M18 | M30 | |||
---|---|---|---|---|---|
Shielded | Shielded | Unshielded | Shielded | Unshielded | |
Model | E2E-X5Y[] | E2E-X10MY[] | E2E-X10Y[] | E2E-X18MY[] | |
Sensing distance | 5 mm ±10% | 10 mm ±10% | 18 mm ±10% | ||
Set distance | 0 to 4 mm | 0 to 8 mm | 0 to 14 mm | ||
Differential travel | 10% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
||||
Standard sensing object | Iron,
18 × 18 × 1 mm |
Iron, 30 × 30 × 1 mm | Iron,
54 × 54 × 1 mm |
||
Response frequency | 25 Hz | ||||
Power supply voltage
(operating voltage range) *1 |
24 to 240 VAC (20 to 264 VAC), 50/60 Hz | ||||
Leakage current | 1.7 mA max. | ||||
Control
output |
Load current *2 | 5 to 300 mA | |||
Residual voltage | Refer to Engineering Data on Data Sheet. | ||||
Indicators | Operation indicator (red) | ||||
Operation mode
(with sensing object approaching) |
Y1 Models: NO
Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
||||
Protection circuits | Surge suppressor | ||||
Ambient temperature range
*1 *2 |
Operating/Storage: -40 to 85°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C,
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying
parts and case |
||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
||||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67 |
||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | ||||
Weight
(packed state) |
Pre-wired Models
Model |
Approx. 130 g | Approx. 175 g | ||
Connector Models | Approx. 40 g | Approx. 90 g | |||
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing surface | PBT | ||||
Clamping nuts | Nickel-plated brass | ||||
Toothed washer | Zinc-plated iron | ||||
Accessories | Instruction manual |
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at
least −25°C.
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the
Sensor has a control output (load current) of 5 to 200 mA max.
Size | M12 | M18 | M30 | |
---|---|---|---|---|
Shielded | Shielded | |||
Model | E2E-X3T1 | E2E-X7T1 | E2E-X10T1 | |
Sensing distance | 3 mm ±10% | 7 mm ±10% | 10 mm ±10% | |
Set distance | 0 to 2.4 mm | 0 to 5.6 mm | 0 to 8 mm | |
Differential travel | 10% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.) |
|||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | |
Response
frequency *1 |
DC | 1 kHz | 0.5 kHz | 0.4 kHz |
AC | 25 Hz | |||
Power supply voltage
(operating voltage range) *2 |
24 to 240 VDC (20 to 264 VDC)
48 to 240 VAC (40 to 264 VAC) |
|||
Leakage current | DC: 1 mA max.
AC: 2 mA max. |
|||
Control
output |
Load current | 5 to 100 mA | ||
Residual
voltage |
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m) |
|||
Indicators | Operation indicator (red), Setting indicator (green) | |||
Operation mode
(with sensing object approaching) |
NO (Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.) | |||
Protection circuits | Load short-circuit protection (20 to 40 VDC only), Surge suppressor | |||
Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
|||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
Weight (packed state) | Approx. 80 g | Approx. 140 g | Approx. 190 g | |
Materials | Case | Nickel-plated brass | ||
Sensing surface | PBT | |||
Clamping nuts | Nickel-plated brass | |||
Toothed washer | Zinc-plated iron | |||
Accessories | Instruction manual |
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a
distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. Power Supply Voltage Waveform:
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
last update: October 11, 2022