Welding Proximity Sensor
last update: September 1, 2025
| Type | Quadruple distance model/
Spatter-resistant Double distance model |
Triple distance model/
Spatter-resistant Triple distance model |
|||||
|---|---|---|---|---|---|---|---|
| Size | M12 | M18 | M30 | M12 | M18 | M30 | |
| Model | E2EW-
(Q)X7[]12 |
E2EW-
(Q)X12[]18 |
E2EW-
(Q)X22[]30 |
E2EW-
(Q)X6[]12 |
E2EW-
(Q)X10[]18 |
E2EW-
(Q)X20[]30 |
|
| Sensing distance | 7 mm ±10% | 12 mm ±10% | 22 mm ±10% | 6 mm ±10% | 10 mm ±10% | 20 mm ±10% | |
| Setting distance | 0 to 4.9 mm | 0 to 8.4 mm | 0 to 15.4 mm | 0 to 4.2 mm | 0 to 7.0 mm | 0 to 14 mm | |
| Differential travel | 15% max. of sensing distance | ||||||
| Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data on catalog.) | ||||||
| Standard sensing object
(Iron) |
21 × 21 ×
1 mm |
36 × 36 ×
1 mm |
66 × 66 ×
1 mm |
18 × 18 ×
1 mm |
30 × 30 ×
1 mm |
60 × 60 ×
1 mm |
|
| Response frequency *1 | 2 Hz (Equipped with a function, which effectively cancels pulse noise of current magnetic field.) | ||||||
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||||
| Current consumption | 720 mW max. (Current consumption: 30 mA max. at power supply voltage of 24 V) | ||||||
| Output configuration | B[] Models: PNP open collector, C[] Models: NPN open collector | ||||||
| Operation mode | 1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) |
||||||
| Control
output |
Load
current |
1-output models (B1,B2,C1,C2): 10 to 30 VDC, Class 2, 200 mA max.
2-output models (B3, C3): 10 to 30 VDC, Class 2, 100 mA max. |
|||||
| Residual
voltage |
1-output models (B1,B2,C1,C2): 2 V max. (Load current: 200 mA, Cable length: 2 m)
2-output models (B3, C3): 2 V max. (Load current: 100 mA, Cable length: 2 m) |
||||||
| Indicator | In the Standard I/O mode (SIO mode):
Operation indicator (orange, lit) and communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) |
||||||
| Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection | ||||||
| Ambient temperature
range |
Operating: 0 to 85 °C, Storage: -15 to 85 °C (with no icing or condensation) *3 | ||||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||||
| Temperature influence | ±20% max. of sensing distance at 23 °C in the temperature range of 0 to 85 °C | ||||||
| Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||||
| Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||||
| Shock resistance
(destruction) |
1,000 m/s2 10 times each in X, Y, and Z directions | ||||||
| Degree of protection | IEC 60529: IP67 | ||||||
| Connection method | Pre-wired Models (Standard cable length: 2 m),
Pre-wired Connector Models (Standard cable length: 0.3 m), M12 Connector Models |
||||||
| Weight
(packed state) |
Pre-wired | Approx. 140 g | Approx. 165 g | Approx. 225 g | Approx. 140 g | Approx. 165 g | Approx. 225 g |
| M12
Pre-wired Smartclick Connector |
Approx. 70 g | Approx. 100 g | Approx. 160 g | Approx. 70 g | Approx. 100 g | Approx. 160 g | |
| M12
Connector |
Approx. 60 g | Approx. 75 g | Approx. 135 g | Approx. 60 g | Approx. 75 g | Approx. 135 g | |
| Materials | Case | E2EW-X[]: Stainless steel (SUS303),
E2EW-QX[]: Fluororesin coating (Base material: (SUS303)) |
|||||
| Sensing
surface |
E2EW-X[]: Stainless steel (SUS303),
E2EW-QX[]: Fluororesin coating (Base material: (SUS303)) |
||||||
| Sensing
surface (Thickness) |
0.4 mm | 0.4 mm | 0.5 mm | 0.4 mm | 0.4 mm | 0.5 mm | |
| Clamping
nuts |
E2EW-X[]: Stainless steel (SUS303),
E2EW-QX[]: Fluororesin coating (Base material: (SUS303)) |
||||||
| Toothed
washers |
Zinc-plated iron | ||||||
| Cable | Vinyl chloride (PVC) | ||||||
| Main IO-Link functions
*2 |
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset | ||||||
| IO-Link
Communi-cation specifi-cations *2 |
IO-Link specification | Ver.1.1 | |||||
| Baud rate | E2EW(-Q) X[]B[]T[]: COM3 (230.4 kbps), E2EW(-Q) X[]B[]D[]: COM2 (38.4 kbps) | ||||||
| Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||||
| Minimum
cycle time |
COM2: 2.3 ms, COM3: 1.0 ms | ||||||
| MTTFd (Year) | 679 | 681 | 681 | 679 | 681 | 681 | |
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||||
*1. The response frequency is an average value. Factory setting: (timer function: ONOFF delay)
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
*3. UL temperature rating is between 0 °C to 60 °C.
| Type | Double distance model/
Spatter-resistant Double distance model |
Single distance model/
Spatter-resistant Single distance model |
||||||
|---|---|---|---|---|---|---|---|---|
| Size | M12 | M18 | M30 | M8 | M12 | M18 | M30 | |
| Model | E2EW-
(Q)X3[]12 |
E2EW-
(Q)X7[]18 |
E2EW-
(Q)X12[]30 |
E2EW-
(Q)X1R5[]8 |
E2EW-
(Q)X2[]12 |
E2EW-
(Q)X5[]18 |
E2EW-
(Q)X10[]30 |
|
| Sensing distance | 3 mm ±10% | 7 mm ±10% | 12 mm ±10% | 1.5 mm ±10% | 2 mm ±10% | 5 mm ±10% | 10 mm ±10% | |
| Setting distance | 0 to 2.1 mm | 0 to 4.9 mm | 0 to 8.4 mm | 0 to 1.05 mm | 0 to 1.4 mm | 0 to 3.5 mm | 0 to 7 mm | |
| Differential travel | 15% max. of sensing distance | 15% max. of
sensing distance |
10% max. of sensing distance | |||||
| Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material
of the sensing object. Refer to Engineering Data on catalog.) |
|||||||
| Standard sensing object
(Iron) |
21 × 21 ×
1 mm |
30 × 30 ×
1 mm |
54 × 54 ×
1 mm |
8 × 8 ×
1 mm |
12 × 12 ×
1 mm |
18 × 18 ×
1 mm |
30 × 30 ×
1 mm |
|
| Response frequency *1 | 80 Hz | 90 Hz | 50 Hz | 100 Hz | 100 Hz | 80 Hz | 40 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | |||||||
| Current consumption | M8 Size: 10 mA max.
M12/M18/M30 Size 1-output models (B1, B2, C1, C2): 16 mA max. 2-output models (B3, C3): 20 mA max. |
|||||||
| Output configuration | B[] Models: PNP open collector,
C[] Models: NPN open collector |
|||||||
| Operation mode | 1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) |
|||||||
| Control
output |
Load current | 1-output models (B1, B2, C1, C2): 10 to 30 VDC, Class 2, 200 mA max.
2-output models (B3, C3): 10 to 30 VDC, Class 2, 100 mA max. |
||||||
| Residual voltage | 1-output models (B1, B2, C1, C2): 2 V max. (Load current: 200 mA, Cable length: 2 m)
2-output models (B3, C3): 2 V max. (Load current: 100 mA, Cable length: 2 m) |
|||||||
| Indicator | Operation indicator (orange LED, lit) | |||||||
| Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit
protection, Output reverse polarity protection |
|||||||
| Ambient temperature range | M8 Size
Operating: -25 to 70°C, Storage: -25 to 70°C (with no icing or condensation) *2 M12/M18/M30 Size Operating: 0 to 85°C, Storage: -15 to 85°C (with no icing or condensation) *2 |
|||||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||||||
| Temperature influence | M8 Size
±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C M12/M18/M30 Size ±20% max. of sensing distance at 23°C in the temperature range of 0 to 85°C |
|||||||
| Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||||||
| Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||||
| Shock resistance
(destruction) |
M8 Size
500 m/s2 10 times each in X, Y, and Z directions M12/M18/M30 Size 1,000 m/s2 10 times each in X, Y, and Z directions |
|||||||
| Degree of protection | IEC 60529: IP67 | |||||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m), M12 Connector Models *3 | |||||||
| Weight
(packed state) |
Pre-wired | Approx.
140 g |
Approx.
165 g |
Approx.
225 g |
Approx.
105 g |
Approx.
140 g |
Approx.
160 g |
Approx.
225 g |
| M12 Pre-wired
Smartclick Connector |
Approx.
70 g |
Approx.
100 g |
Approx.
160 g |
--- | Approx.
70 g |
Approx.
95 g |
Approx.
160 g |
|
| M12 Connector | --- | --- | --- | Approx.
43 g |
Approx.
60 g |
Approx.
75 g |
Approx.
135 g |
|
| Materials | Case | E2EW-X[]: Stainless steel (SUS303), E2EW-QX[]: Fluororesin coating (Base material:
(SUS303)) |
||||||
| Sensing surface | E2EW-X[]: Stainless steel (SUS303), E2EW-QX[]: Fluororesin coating (Base material:
(SUS303)) |
|||||||
| Sensing surface
(Thickness) |
0.4 mm | 0.4 mm | 0.5 mm | 0.4 mm | 0.8 mm | 0.8 mm | 0.8 mm | |
| Clamping nuts | E2EW-X[]: Stainless steel (SUS303), E2EW-QX[]: Fluororesin coating (Base material:
(SUS303)) |
|||||||
| Toothed
washers |
Zinc-plated iron | |||||||
| Cable | Vinyl chloride (PVC) | |||||||
| MTTFd (Year) | 2,013 | 1,199 | 1,013 | 3,427 | 2,013 | 1,199 | 1,013 | |
| Accessories | Instruction manual, Clamping nuts, Toothed washer | |||||||
| Type | Double distance model/
Spatter-resistant Double distance model |
||||
|---|---|---|---|---|---|
| Size | M8 | M12 | M18 | M30 | |
| Item Model | E2EW-
(Q)X2D[]8 |
E2EW-
(Q)X3D[]12 |
E2EW-
(Q)X7D[]18 |
E2EW-
(Q)X12D[]30 |
|
| Sensing distance | 2 mm ±10% | 3 mm ±10% | 7 mm ±10% | 12 mm ±10% | |
| Setting distance | 0 to 1.4 mm | 0 to 2.1 mm | 0 to 4.9 mm | 0 to 8.4 mm | |
| Differential travel | 15% max. of sensing distance | ||||
| Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material
of the sensing object. Refer to Engineering Data on Catalog.) |
||||
| Standard sensing object
(Iron) |
12 × 12 × 1 mm | 21 × 21 × 1 mm | 30 × 30 × 1 mm | 54 × 54 × 1 mm | |
| Response frequency *1 | 100 Hz | 80 Hz | 90 Hz | 50 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Leakage current | 0.8 mA max. | ||||
| Output configuration | D[] models: Polarity
D1-T models: No polarity |
||||
| Operation mode | D1 models: NO (Normally open),
D2 models: NC (Normally closed) |
||||
| Control
output |
Load current | 3 to 100 mA | |||
| Residual voltage | Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) |
||||
| Indicator | D1 models: Operation indicator (orange LED, lit) and communication indicator (green LED, not lit)
D2 models: Operation indicator (orange LED, lit) |
||||
| Protection circuits | Surge suppressor, Output short-circuit protection | ||||
| Ambient temperature range | M8 Size
Operating: -10 to 70°C, Storage: -25 to 70°C (with no icing or condensation) *2 M12/M18/M30 Size Operating: 0 to 85°C, Storage: -15 to 85°C (with no icing or condensation) *2 |
||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | M8 Size
±20% max. of sensing distance at 23°C in the temperature range of -10 to 70°C M12/M18/M30 Size ±20% max. of sensing distance at 23°C in the temperature range of 0 to 85°C |
||||
| Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | M8 Size
500 m/s2 10 times each in X, Y, and Z directions M12/M18/M30 Size 1,000 m/s2 10 times each in X, Y, and Z directions |
||||
| Degree of protection | IEC 60529: IP67 | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard
cable length: 0.3 m) |
||||
| Weight
(packed state) |
Pre-wired | Approx. 105 g | Approx. 140 g | Approx. 165 g | Approx. 225 g |
| M12 Pre-wired
Smartclick Connector |
Approx. 65 g | Approx. 70 g | Approx. 100 g | Approx. 160 g | |
| Materials | Case | E2EW-X[]: Stainless steel (SUS303), E2EW-QX[]: Fluororesin coating (Base material:
(SUS303)) |
|||
| Sensing surface | E2EW-X[]: Stainless steel (SUS303), E2EW-QX[]: Fluororesin coating (Base material:
(SUS303)) |
||||
| Sensing surface
(Thickness) |
0.2 mm | 0.4 mm | 0.4 mm | 0.5 mm | |
| Clamping nuts | E2EW-X[]: Stainless steel (SUS303), E2EW-QX[]: Fluororesin coating (Base material:
(SUS303)) |
||||
| Toothed
washers |
Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) | ||||
| MTTFd (Year) | 2,041 | 2,015 | 1,979 | 1,979 | |
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Type | Single distance model/
Spatter-resistant Single distance model |
||||
|---|---|---|---|---|---|
| Size | M8 | M12 | M18 | M30 | |
| Item Model | E2EW-
(Q)X1R5D[]8 |
E2EW-
(Q)X2D[]12 |
E2EW-
(Q)X5D[]18 |
E2EW-
(Q)X10D[]30 |
|
| Sensing distance | 1.5 mm ±10% | 2 mm ±10% | 5 mm ±10% | 10 mm ±10% | |
| Setting distance | 0 to 1.05 mm | 0 to 1.4 mm | 0 to 3.5 mm | 0 to 7 mm | |
| Differential travel | 15% max. of
sensing distance |
10% max. of sensing distance | |||
| Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material
of the sensing object. Refer to Engineering Data on Catalog.) |
||||
| Standard sensing object
(Iron) |
8 × 8 × 1 mm | 12 × 12 × 1 mm | 18 × 18 × 1 mm | 30 × 30 × 1 mm | |
| Response frequency *1 | 100 Hz | 100 Hz | 80 Hz | 40 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Leakage current | 0.8 mA max. | ||||
| Output configuration | D[] models: Polarity
D1-T models: No polarity |
||||
| Operation mode | D1 models: NO (Normally open),
D2 models: NC (Normally closed) |
||||
| Control
output |
Load current | 3 to 100 mA | |||
| Residual voltage | Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) |
||||
| Indicator | D1 models: Operation indicator (orange LED, lit) and communication indicator (green LED, not lit)
D2 models: Operation indicator (orange LED, lit) |
||||
| Protection circuits | Surge suppressor, Output short-circuit protection | ||||
| Ambient temperature range | M8 Size
Operating: -25 to 70°C, Storage: -25 to 70°C (with no icing or condensation) *2 M12/M18/M30 Size Operating: 0 to 85°C, Storage: -15 to 85°C (with no icing or condensation) *2 |
||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | M8 Size
±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C M12/M18/M30 Size ±20% max. of sensing distance at 23°C in the temperature range of 0 to 85°C |
||||
| Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance
(destruction) |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | M8 Size
500 m/s2 10 times each in X, Y, and Z directions M12/M18/M30 Size 1,000 m/s2 10 times each in X, Y, and Z directions |
||||
| Degree of protection | IEC 60529: IP67 | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard
cable length: 0.3 m) |
||||
| Weight
(packed state) |
Pre-wired | Approx. 105 g | Approx. 140 g | Approx. 160 g | Approx. 225 g |
| M12 Pre-wired
Smartclick Connector |
Approx. 65 g | Approx. 70 g | Approx. 95 g | Approx. 160 g | |
| Materials | Case | E2EW-X[]: Stainless steel (SUS303), E2EW-QX[]: Fluororesin coating (Base material:
(SUS303)) |
|||
| Sensing surface | E2EW-X[]: Stainless steel (SUS303), E2EW-QX[]: Fluororesin coating (Base material:
(SUS303)) |
||||
| Sensing surface
(Thickness) |
0.4 mm | 0.8 mm | 0.8 mm | 0.8 mm | |
| Clamping nuts | E2EW-X[]: Stainless steel (SUS303), E2EW-QX[]: Fluororesin coating (Base material:
(SUS303)) |
||||
| Toothed
washers |
Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) | ||||
| MTTFd (Year) | 2,041 | 2,015 | 1,979 | 1,979 | |
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
last update: September 1, 2025