GL Certification Standards (German Marine Standards)
Programmable Controllers
|
Model |
Environmental category |
Requirement class |
|
CJ1 |
C: EMC2 |
Class 3 |
|
CPM1A / CPM1 |
C: EMC2 |
Class 3 |
|
CQM1 |
C: EMC2 |
Class 3 |
Note:
1. The
above table lists series names. Ask your OMRON representative for details on
specific model numbers.
2. Model certification has not been received for usage on the deck, in the
bridge, or in locations subject to strong vibration.
Model certification for the GL (Germanischser Lloyd) was made according to the
Regulations for the Performance of Type Test, Part 2, Edition 2003.
Refer to the following tables for environmental categories and requirement
classes.
|
Environmental Category |
Environmental Conditions |
|
Closed Area |
Open Deck Area |
|
Temperature |
Relative Humidity |
Vibrations |
Temperature |
Relative Humidity |
Vibrations |
|
A |
0 to 45°C |
to 100% |
0.7 g (Curve 1) |
|
|
|
|
B |
0 to 45°C |
to 100% |
4 g (Curve 2) |
|
|
|
|
C |
0 to 55°C |
to 100% |
0.7 g (Curve 1) |
|
|
|
|
D |
0 to 55°C |
to 100% |
4 g (Curve 2) |
|
|
|
|
E |
0 to 40°C |
to 80% |
0.7 g (Curve 1) |
|
|
|
|
F |
|
|
|
-25 to 45°C |
to 100% |
0.7 g (Curve 1) |
|
G |
|
|
|
-25 to 45°C |
to 100% |
2.3 g |
|
Requirement Class |
Extent of damage |
|
Effects on persons |
Effects on the environment |
Technical damage |
|
1 |
none |
none |
insignificant |
|
2 |
slight injury |
insignificant |
minor |
|
3 |
serious, irreversible injury |
significant |
serious |
|
4 |
loss of human life |
critical |
considerable |
|
5 |
much loss of human life |
catastrophic |
loss |
|