* These Units are also available with a
DCN-TB4 Terminal Conversion Adapter included in the package. Add "(-B)"
to the end of the model number to receive the Adapter as well.
CompoNet Master Boards
|
Name |
Appearance |
Specifications |
Model |
Standards |
|
PCI Bus type |
 |
PCI bus Rev2.2 5V |
3G8F7-CRM21 |
CE
|
|
CompactPCI
Bus type |
 |
PICMG 2.0 R3.0 5V 32-Bit 3U |
3G8F8-CRM21 |
CompoNet Slave Units
Word Slave Units
• Digital I/O Slave
Units
|
Name |
Appearance |
Specifications |
Communications Cables |
Model |
Standards |
|
Round Cable I |
Round Cable II |
Standard Flat Cable I |
Sheathed Flat Cable II |
|
Two tier Screw Terminal Block |
 |
Inputs |
8 inputs |
NPN |
Yes |
Yes |
Yes |
Yes |
CRT1-ID08 |
CE, UL, UL (Class I Div2), NK |
|
PNP |
CRT1-ID08-1 |
|
Outputs |
8 outputs |
NPN |
CRT1-OD08 |
|
PNP |
CRT1-OD08-1 |
|
Inputs |
16 inputs |
NPN |
CRT1-ID16
* |
CE, UL, UL (Class I Div2), CSA, NK |
|
PNP |
CRT1-ID16-1
* |
|
Outputs |
16 outputs |
NPN |
CRT1-OD16
* |
|
PNP |
CRT1-OD16-1
* |
|
Inputs/ Outputs |
8 inputs/ 8 outputs |
NPN |
CRT1-MD16 |
CE, UL, UL (Class I Div2), NK |
|
PNP |
CRT1-MD16-1 |
|
Screw Terminal Block with Relay
Outputs |
 |
Outputs |
8 outputs |
Contacts |
Yes |
Yes |
Yes |
Yes |
CRT1-ROS08 |
CE, cULus, cULus (Class I Dis2), NK |
|
16 outputs |
CRT1-ROS16 |
|
Screw Terminal Block with SSR
Outputs |
Outputs |
8 outputs |
SSR |
CRT1-ROF08 |
-- |
|
16 outputs |
CRT1-ROF16 |
|
Three-tier Screw Terminal Block
(Without Short-circuit and
Disconnected Line Detection) |
 |
Inputs |
8 inputs |
NPN |
Yes |
Yes |
Yes |
Yes |
CRT1-ID08TA |
CE, cULus, cULus (Class I Dis2) |
|
PNP |
CRT1-ID08TA-1 |
|
Outputs |
8 outputs |
NPN |
CRT1-OD08TA |
|
PNP |
CRT1-OD08TA-1 |
|
Inputs |
16 inputs |
NPN |
CRT1-ID16TA |
|
PNP |
CRT1-ID16TA-1 |
|
Outputs |
16 outputs |
NPN |
CRT1-OD16TA |
|
PNP |
CRT1-OD16TA-1 |
|
Inputs/ outputs |
8 inputs and 8 outputs |
NPN |
CRT1-MD16TA |
|
PNP |
CRT1-MD16TA-1 |
|
Three-tier Screw Terminal Block
(With Short-circuit and Disconnected
Line Detection) |
Inputs |
8 inputs |
NPN |
Yes |
Yes |
Yes |
Yes |
CRT1-ID08TAH |
|
PNP |
CRT1-ID08TAH-1 |
|
Outputs |
8 outputs |
NPN |
CRT1-OD08TAH |
|
PNP |
CRT1-OD08TAH-1 |
|
Inputs |
16 inputs |
NPN |
CRT1-ID16TAH |
|
PNP |
CRT1-ID16TAH-1 |
|
Outputs |
16 outputs |
NPN |
CRT1-OD16TAH |
|
PNP |
CRT1-OD16TAH-1 |
|
Inputs/ outputs |
8 inputs and 8 outputs |
NPN |
CRT1-MD16TAH |
|
PNP |
CRT1-MD16TAH-1 |
|
e-CON Connectors
(Without Short-circuit and
Disconnected Line Detection) |
 |
Inputs |
16 inputs |
NPN |
Yes |
Yes |
Yes |
Yes |
CRT1-ID16S |
CE, cULus, cULus (Class I Dis2) |
|
PNP |
CRT1-ID16S-1 |
|
Outputs |
16 outputs |
NPN |
CRT1-OD16S |
|
PNP |
CRT1-OD16S-1 |
|
Inputs/ outputs |
8 inputs and 8 outputs |
NPN |
CRT1-MD16S |
|
PNP |
CRT1-MD16S-1 |
|
Inputs |
32 inputs |
NPN |
CRT1-ID32S |
|
PNP |
CRT1-ID32S-1 |
|
Outputs |
32 outputs |
NPN |
CRT1-OD32S |
|
PNP |
CRT1-OD32S-1 |
|
Inputs/ outputs |
16 inputs and 16 outputs |
NPN |
CRT1-MD32S |
|
PNP |
CRT1-MD32S-1 |
|
e-CON Connectors
(With Short-circuit and Disconnected
Line Detection) |
 |
Inputs |
16 inputs |
NPN |
Yes |
Yes |
Yes |
Yes |
CRT1-ID16SH |
|
PNP |
CRT1-ID16SH-1 |
|
Outputs |
16 outputs |
NPN |
CRT1-OD16SH |
|
PNP |
CRT1-OD16SH-1 |
|
Inputs/ outputs |
8 inputs and 8 outputs |
NPN |
CRT1-MD16SH |
|
PNP |
CRT1-MD16SH-1 |
|
Inputs |
32 inputs |
NPN |
CRT1-ID32SH |
|
PNP |
CRT1-ID32SH-1 |
|
Outputs |
32 outputs |
NPN |
CRT1-OD32SH |
|
PNP |
CRT1-OD32SH-1 |
|
Inputs/ outputs |
16 inputs and 16 outputs |
NPN |
CRT1-MD32SH |
|
PNP |
CRT1-MD32SH-1 |
|
e-CON Connectors*
(Without Short-circuit and
Disconnected Line Detection) |
 |
Inputs |
8 inputs |
NPN |
Yes |
Yes |
Yes |
Yes |
CRT1-VID08S |
|
PNP |
CRT1-VID08S-1 |
|
Outputs |
8 outputs |
NPN |
CRT1-VOD08S |
|
PNP |
CRT1-VOD08S-1 |
|
MIL Connectors * |
 |
Inputs |
16 inputs |
NPN |
Yes |
Yes |
Yes |
Yes |
CRT1-VID16ML |
CE, cULus, cULus (Class I Dis2), NK |
|
PNP |
CRT1-VID16ML-1 |
|
Outputs |
16 outputs |
NPN |
CRT1-VOD16ML |
|
PNP |
CRT1-VOD16ML-1 |
|
MIL Connectors * |
 |
Inputs |
32 inputs |
NPN |
Yes |
Yes |
Yes |
Yes |
CRT1-VID32ML |
CE, cULus, cULus (Class I Dis2), NK |
|
PNP |
CRT1-VID32ML-1 |
|
Outputs |
32 outputs |
NPN |
CRT1-VOD32ML |
|
PNP |
CRT1-VOD32ML-1 |
|
Inputs/ outputs |
16 inputs and 16 outputs |
NPN |
CRT1-VMD32ML |
|
PNP |
CRT1-VMD32ML-1 |
|
Clamp Terminal Blocks |
 |
Inputs |
8 inputs |
NPN |
Yes |
Yes |
Yes |
Yes |
CRT1-ID08SL |
CE, NK |
|
PNP |
CRT1-ID08SL-1 |
|
Outputs |
8 outputs |
NPN |
CRT1-OD08SL |
|
PNP |
CRT1-OD08SL-1 |
|
Inputs |
16 inputs |
NPN |
CRT1-ID16SL |
|
PNP |
CRT1-ID16SL-1 |
|
Outputs |
16 outputs |
NPN |
CRT1-OD16SL |
|
PNP |
CRT1-OD16SL-1 |
|
Inputs/ outputs |
8 inputs and 8 outputs |
NPN |
CRT1-MD16SL |
|
PNP |
CRT1-MD16SL-1 |
* These Units are also available
with a DCN-TB4 Terminal Conversion Adapter included in the package. Add
"(-B)" to the end of the model number to receive the Adapter as well.
• Analog I/O Slave
Units
|
Name |
Appearance |
Specifications |
Communications Cables |
Model |
Standards |
|
Round Cable I |
Round Cable II |
Standard Flat Cable I |
Sheathed Flat Cable II |
|
Analog I/O Slave Units * |
 |
Analog Inputs |
4 inputs |
Yes |
Yes |
Yes |
Yes |
CRT1-AD04 |
CE, UL, UL (Class 1 Div2), CSA, NK |
|
Analog outputs |
2 outputs |
CRT1-DA02 |
|
MIL Connector Type |
 |
Analog Inputs |
4 inputs |
CRT1-VAD04ML |
CE, cULus, cULus (Class I Dis2) |
|
Analog outputs |
2 outputs |
CRT1-VDA02ML |
|
e-CON Connector Type |
 |
Analog Inputs |
4 inputs |
CRT1-VAD04S |
|
Analog outputs |
2 outputs |
CRT1-VDA02S |
|
Numerical Indicator,
MIL Connector Type |
 |
Analog inputs (Channel Insulation) |
2 inputs |
Yes |
Yes |
Yes |
Yes |
CRT1-VAD02MLD |
CE
|
|
Analog outputs |
2 outputs |
CRT1-VDA02MLD |
|
Numerical Indicator,
e-CON Connector Type |
 |
Analog inputs (Channel Insulation) |
2 inputs |
CRT1-VAD02SD |
|
Analog outputs |
2 outputs |
CRT1-VDA02SD |
* These Units are also available
with a DCN-TB4 Terminal Conversion Adapter included in the package. Add
"(-B)" to the end of the model number to receive the Adapter as well.
• Temperature Input
Units
|
Name |
Appearance |
Specifications |
Communications Cable |
Model |
Standards |
|
Round Cable I |
Round Cable II |
Standard Flat Cable I |
Sheathed Flat Cable II |
|
Temperature Input Units |
 |
Thermocouple Input |
4 inputs |
Switchable between (R, S, K, J, T,
E, B, N, L, U, W, PL2) |
Yes |
Yes |
Yes |
Yes |
CRT1-TS04T |
CE, cULus, cULus (Class I Dis2), NK |
|
Platinum- resistance thermometer
input |
PT100 (-200 to 850°C)
PT100 (-200 to 2000°C) |
CRT1-TS04P |
• Expansion
Units
|
Name |
Appearance |
Specifications |
Model |
Standards |
|
Expansion Units |
 |
Inputs |
8 inputs |
NPN |
One Expansion Unit can be mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16, or CRT1-ROF16 Digital I/O Slave. |
XWT-ID08 |
CE, cULus, cULus (Class I Dis2), NK |
|
PNP |
XWT-ID08-1 |
|
Outputs |
8 outputs |
NPN |
XWT-OD08 |
|
PNP |
XWT-OD08-1 |
|
Inputs |
16 inputs |
NPN |
XWT-ID16 |
|
PNP |
XWT-ID16-1 |
|
Outputs |
16 outputs |
NPN |
XWT-OD16 |
|
PNP |
XWT-OD16-1 |
|
Expansion Units e-CON Connector type |
--- |
Digital outputs |
8 outputs |
NPN |
One Expansion Unit can be mounted to one CRT1-VAD02[][]D or
CRT1-VDA02[][]D Analog I/O Slave Unit. |
XWT-VOD08S |
--- |
|
Digital outputs |
8 outputs |
PNP |
XWT-VOD08S-1 |
|
Digital inputs & outputs |
4 inputs/
4 outputs |
NPN |
XWT-VMD08S |
|
Digital inputs & outputs |
4 inputs/
4 outputs |
PNP |
XWT-VMD08S-1 |
|
Expansion Units MIL Connector type |
--- |
Digital outputs |
16 inputs |
NPN |
XWT-VOD16ML |
|
Digital outputs |
16 inputs |
PNP |
XWT-VOD16ML-1 |
|
Digital inputs & outputs |
8 inputs/
8 outputs |
NPN |
XWT-VMD16ML |
|
Digital inputs & outputs |
8 inputs/
8 outputs |
PNP |
XWT-VMD16ML-1 |
Bit Slave Units
• Compact Connectors
• Repeater Unit
|
Name |
Appearance |
Specifications |
Communications Cables |
Model |
Standards |
|
Round Cable I |
Round Cable II |
Standard Flat Cable I |
Sheathed Flat Cable II |
|
Repeater Unit * |
 |
A sub-trunk line can be connected
downstream (for trunk-branch line configuration) or further
branching is enabled downstream (for configurations with no wiring
restrictions) in the same way as for a Master Unit. A Repeater
Unit can be used to branch the trunk line and increase the number
of connected Units, as well as to extend the length of the
communications line. |
Yes |
Yes |
Yes |
Yes |
CRS1-RPT01 |
CE, UL, UL (Class I Div2), LR, NK |
* These Units are also available
with a DCN-TB4 Terminal Conversion Adapter included in the package. Add
"(-B)" to the end of the model number to receive the Adapter as well.
• SmartSlice GRT1
Series: CompoNet Communications Unit
|
Name |
Appearance |
Specifications |
Model |
Standards |
|
CompoNet Communications Unit |
 |
Up to 64 Slice I/O Units can be
connected
(Inputs: 32 bytes maximum, Output: 32 bytes maximum) |
GRT1-CRT |
CE, cULus (Class I Dis2), Lloyd |
• Sensor Communications
Unit
|
Name |
Appearance |
I/O
classification |
Allocated bits |
Internal circuit power supply |
I/O power supply voltage |
Connected
Controller model |
Model |
Standards |
|
Sensor Communications Unit |
 |
Input and output |
160 bits max. |
Supplied along with communications
power |
24 VDC |
ZS-LDC[][]
ZS-MDC[][]
ZS-HLDC[][]
ZFV-CA[][]
ZG-WDC[][] |
ZS-CRT |
CE |

CompoNet Slave Unit Functions
The Slave Units provide Smart Functions
that powerfully aid in everything from building the system and initial
system startup to preventive system maintenance. The Smart Functions
include functions for monitoring the operation time, changes in operating
values, and other values, as well as functions that provide warnings for
maintenance based on ON/OFF counts, total operating time, and other
counted values.
Yes: Supported, ---: Not
supported
|
Function |
Digital I/O Slave Units |
|
2-tier Terminal block |
|
CRT1-[]D08(-1) |
CRT1-[]D16(-1) |
CRT1-ROS08 |
CRT1-ROS16 |
CRT1-ROF08 |
CRT1-ROF16 |
|
Input Units |
Output Units |
Input Units |
Output Units |
I/O
Units |
Output Units |
Output Units |
|
Operation Time Monitor |
Yes |
|
Contact Operation
Monitor (See note.) |
Yes |
|
Total ON Time Monitor
(See note.) |
Yes |
|
Automatic Baud Rate
Detection |
Yes |
|
Unit Conduction Time
Monitor |
Yes |
|
Naming Units |
Yes |
|
Naming Connected
Devices |
Yes |
|
Network Power Voltage
Monitor |
Yes |
|
I/O Power Status
Monitor |
Yes |
--- |
|
Communications Error
History Monitor |
Yes |
|
Input Filter |
Yes |
--- |
Yes |
--- |
Yes |
--- |
|
Communications Error
Output |
--- |
Yes |
--- |
Yes |
Yes |
Yes |
|
Preventing Malfunctions
Caused by Inrush Current at I/O Startup |
Yes |
--- |
Yes |
--- |
Yes |
--- |
|
Power Short-circuit
Detection |
--- |
|
Unconnected Line
Detection |
--- |
|
Load Short-circuit
Detection |
--- |
|
Disconnected Line
Detection |
--- |
|
Removable Terminal
Block Structure |
Yes |
|
Expansion Using
Expansion Units |
--- |
Yes |
--- |
Yes |
--- |
Yes |
|
Scaling |
--- |
|
Last Maintenance Date |
Yes |
|
Cumulative Counter |
--- |
|
Moving Average |
--- |
|
Setting the Number of
AD Conversion Points |
--- |
|
Rate of Change |
--- |
|
Comparator |
--- |
|
Peak/Bottom Hold |
--- |
|
Top/Valley Hold |
--- |
|
User Adjustment |
--- |
|
Top/Valley Count |
--- |
|
Temperature Range Total
Time Count |
--- |
|
Input Temperature
Variation Detection |
--- |
|
Input Error Detection
Disable Function |
--- |
Note: The Contact Operation Monitor and the
Total ON Time Monitor cannot be used at the same time for the same
contact.
Yes: Supported, ---: Not
supported
|
Function |
Digital I/O Slave Units |
|
3-tier Terminal block |
|
CRT1-[]D08TA(-1) |
CRT1-[]D08TAH(-1) * |
CRT1-[]D16TA(-1) |
CRT1-[]D16TAH(-1) * |
|
Input Units |
Output Units |
Input Units |
Output Units |
Input Units |
Output Units |
I/O
Units |
Input Units |
Output Units |
I/O
Units |
|
Operation Time Monitor |
Yes |
|
Contact Operation
Monitor (See note.) |
Yes |
|
Total ON Time Monitor
(See note.) |
Yes |
|
Automatic Baud Rate
Detection |
Yes |
|
Unit Conduction Time
Monitor |
Yes |
|
Naming Units |
Yes |
|
Naming Connected
Devices |
Yes |
|
Network Power Voltage
Monitor |
Yes |
|
I/O Power Status
Monitor |
Yes |
|
Communications Error
History Monitor |
Yes |
|
Input Filter |
Yes |
--- |
Yes |
--- |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
|
Communications Error
Output |
--- |
Yes |
--- |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
|
Preventing Malfunctions
Caused by Inrush Current at I/O Startup |
Yes |
--- |
Yes |
--- |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
|
Power Short-circuit
Detection |
--- |
Yes |
--- |
--- |
Yes |
--- |
Yes |
|
Unconnected Line
Detection |
--- |
Yes |
--- |
--- |
Yes |
--- |
Yes |
|
Load Short-circuit
Detection |
--- |
--- |
Yes |
--- |
--- |
Yes |
Yes |
|
Disconnected Line
Detection |
--- |
--- |
Yes |
--- |
--- |
Yes |
Yes |
|
Removable Terminal
Block Structure |
Yes |
|
Expansion Using
Expansion Units |
--- |
|
Scaling |
--- |
|
Last Maintenance Date |
Yes |
|
Cumulative Counter |
--- |
|
Moving Average |
--- |
|
Setting the Number of
AD Conversion Points |
--- |
|
Rate of Change |
--- |
|
Comparator |
--- |
|
Peak/Bottom Hold |
--- |
|
Top/Valley Hold |
--- |
|
User Adjustment |
--- |
|
Top/Valley Count |
--- |
|
Temperature Range Total
Time Count |
--- |
|
Input Temperature
Variation Detection |
--- |
|
Input Error Detection
Disable Function |
--- |
Note: The Contact Operation Monitor and the
Total ON Time Monitor cannot be used at the same time for the same
contact.
* With Short-circuit and Disconnected Line
Detection
Yes: Supported, ---: Not
supported
|
Function |
Digital I/O Slave Units |
|
Units with e-CON
Connectors |
|
CRT1-[]D16S(-1) |
CRT1-[]D16SH(-1) * |
CRT1-[]D32S(-1) |
CRT1-[]D32SH(-1) * |
|
Input Units |
Output Units |
I/O Units |
Input Units |
Output Units |
I/O Units |
Input Units |
Output Units |
I/O Units |
Input Units |
Output Units |
I/O Units |
|
Operation Time Monitor |
Yes |
|
Contact Operation
Monitor (See note.) |
Yes |
|
Total ON Time Monitor
(See note.) |
Yes |
|
Automatic Baud Rate
Detection |
Yes |
|
Unit Conduction Time
Monitor |
Yes |
|
Naming Units |
Yes |
|
Naming Connected
Devices |
Yes |
|
Network Power Voltage
Monitor |
Yes |
|
I/O Power Status
Monitor |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
|
Communications Error
History Monitor |
Yes |
|
Input Filter |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
|
Communications Error
Output |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
|
Preventing Malfunctions
Caused by Inrush Current at I/O Startup |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
|
Power Short-circuit
Detection |
--- |
Yes |
--- |
Yes |
--- |
Yes |
--- |
Yes |
|
Unconnected Line
Detection |
--- |
Yes |
--- |
Yes |
--- |
Yes |
--- |
Yes |
|
Load Short-circuit
Detection |
--- |
--- |
Yes |
Yes |
--- |
--- |
Yes |
Yes |
|
Disconnected Line
Detection |
--- |
--- |
Yes |
Yes |
--- |
--- |
Yes |
Yes |
|
Removable Terminal
Block Structure |
--- |
|
Expansion Using
Expansion Units |
--- |
|
Scaling |
--- |
|
Last Maintenance Date |
Yes |
|
Cumulative Counter |
--- |
|
Moving Average |
--- |
|
Setting the Number of
AD Conversion Points |
--- |
|
Rate of Change |
--- |
|
Comparator |
--- |
|
Peak/Bottom Hold |
--- |
|
Top/Valley Hold |
--- |
|
User Adjustment |
--- |
|
Top/Valley Count |
--- |
|
Temperature Range Total
Time Count |
--- |
|
Input Temperature
Variation Detection |
--- |
|
Input Error Detection
Disable Function |
--- |
Note: The Contact Operation Monitor and the
Total ON Time Monitor cannot be used at the same time for the same
contact.
* With Short-circuit and Disconnected Line
Detection
Yes: Supported, ---: Not
supported
|
Function |
Digital I/O Slave Units |
|
Units with e-CON
Connectors |
Units with MIL
Connectors |
|
CRT1-V[]D08S(-1) |
CRT1-V[]D16ML(-1) |
CRT1-V[]D32ML(-1) |
|
Input Units |
Output Units |
Input Units |
Output Units |
Input Units |
Output Units |
I/O
Units |
|
Operation Time Monitor |
Yes |
|
Contact Operation
Monitor (See note.) |
Yes |
|
Total ON Time Monitor
(See note.) |
Yes |
|
Automatic Baud Rate
Detection |
Yes |
|
Unit Conduction Time
Monitor |
Yes |
|
Naming Units |
Yes |
|
Naming Connected
Devices |
Yes |
|
Network Power Voltage
Monitor |
Yes |
|
I/O Power Status
Monitor |
--- |
Yes |
Yes |
|
Communications Error
History Monitor |
Yes |
|
Input Filter |
Yes |
--- |
Yes |
--- |
Yes |
--- |
Yes |
|
Communications Error
Output |
--- |
Yes |
--- |
Yes |
--- |
Yes |
Yes |
|
Preventing Malfunctions
Caused by Inrush Current at I/O Startup |
Yes |
--- |
Yes |
--- |
Yes |
--- |
Yes |
|
Power Short-circuit
Detection |
--- |
|
Unconnected Line
Detection |
--- |
|
Load Short-circuit
Detection |
--- |
|
Disconnected Line
Detection |
--- |
|
Removable Terminal
Block Structure |
--- |
|
Expansion Using
Expansion Units |
--- |
|
Scaling |
--- |
|
Last Maintenance Date |
Yes |
|
Cumulative Counter |
--- |
|
Moving Average |
--- |
|
Setting the Number of
AD Conversion Points |
--- |
|
Rate of Change |
--- |
|
Comparator |
--- |
|
Peak/Bottom Hold |
--- |
|
Top/Valley Hold |
--- |
|
User Adjustment |
--- |
|
Top/Valley Count |
--- |
|
Temperature Range Total
Time Count |
--- |
|
Input Temperature
Variation Detection |
--- |
|
Input Error Detection
Disable Function |
--- |
Note: The Contact Operation Monitor and the
Total ON Time Monitor cannot be used at the same time for the same
contact.
Yes: Supported, ---: Not
supported
|
Function |
Digital I/O Slave Units |
|
Units with Screw-less
Clamp Terminals |
|
CRT1-[]D08SL(-1) |
CRT1-[]D16SL(-1) |
|
Input Units |
Output Units |
Input Units |
Output Units |
I/O Units |
|
Operation Time Monitor |
Yes |
|
Contact Operation
Monitor (See note.) |
Yes |
|
Total ON Time Monitor
(See note.) |
Yes |
|
Automatic Baud Rate
Detection |
Yes |
|
Unit Conduction Time
Monitor |
Yes |
|
Naming Units |
Yes |
|
Naming Connected
Devices |
Yes |
|
Network Power Voltage
Monitor |
Yes |
|
I/O Power Status
Monitor |
Yes |
|
Communications Error
History Monitor |
Yes |
|
Input Filter |
Yes |
--- |
Yes |
--- |
Yes |
|
Communications Error
Output |
--- |
Yes |
--- |
Yes |
Yes |
|
Preventing Malfunctions
Caused by Inrush Current at I/O Startup |
Yes |
--- |
Yes |
--- |
Yes |
|
Power Short-circuit
Detection |
--- |
|
Unconnected Line
Detection |
--- |
|
Load Short-circuit
Detection |
--- |
|
Disconnected Line
Detection |
--- |
|
Removable Terminal
Block Structure |
Yes |
|
Expansion Using
Expansion Units |
--- |
|
Scaling |
--- |
|
Last Maintenance Date |
Yes |
|
Cumulative Counter |
--- |
|
Moving Average |
--- |
|
Setting the Number of
AD Conversion Points |
--- |
|
Rate of Change |
--- |
|
Comparator |
--- |
|
Peak/Bottom Hold |
--- |
|
Top/Valley Hold |
--- |
|
User Adjustment |
--- |
|
Top/Valley Count |
--- |
|
Temperature Range Total
Time Count |
--- |
|
Input Temperature
Variation Detection |
--- |
|
Input Error Detection
Disable Function |
--- |
Note: The Contact Operation Monitor and the
Total ON Time Monitor cannot be used at the same time for the same
contact.
Yes: Supported, ---: Not
supported
|
Function |
Analog I/O Slave Units |
|
2-tier Terminal block |
Units with e-CON
Connectors |
Units with MIL
Connectors |
|
CRT1-AD04
CRT1-DA02 |
CRT1-VAD04S
CRT1-VDA02S |
CRT1-VAD04ML
CRT1-VDA02ML |
|
Input Units |
Output Units |
Input Units |
Output Units |
Input Units |
Output Units |
|
Operation Time Monitor |
--- |
|
Contact Operation
Monitor (See note.) |
--- |
|
Total ON Time Monitor
(See note.) |
--- |
|
Automatic Baud Rate
Detection |
Yes |
|
Unit Conduction Time
Monitor |
Yes |
|
Naming Units |
Yes |
|
Naming Connected
Devices |
Yes |
|
Network Power Voltage
Monitor |
Yes |
|
I/O Power Status
Monitor |
--- |
|
Communications Error
History Monitor |
Yes |
|
Input Filter |
--- |
|
Communications Error
Output |
--- |
Yes |
--- |
Yes |
--- |
Yes |
|
Preventing Malfunctions
Caused by Inrush Current at I/O Startup |
--- |
|
Power Short-circuit
Detection |
--- |
|
Unconnected Line
Detection |
--- |
|
Load Short-circuit
Detection |
--- |
|
Disconnected Line
Detection |
Yes |
--- |
Yes |
--- |
Yes |
--- |
|
Removable Terminal
Block Structure |
Yes |
|
Expansion Using
Expansion Units |
--- |
|
Scaling |
Yes |
|
Last Maintenance Date |
Yes |
|
Cumulative Counter |
Yes |
|
Moving Average |
Yes |
--- |
Yes |
--- |
Yes |
--- |
|
Setting the Number of
AD Conversion Points |
Yes |
--- |
Yes |
--- |
Yes |
--- |
|
Rate of Change |
Yes |
--- |
Yes |
--- |
Yes |
--- |
|
Comparator |
Yes |
--- |
Yes |
--- |
Yes |
--- |
|
Peak/Bottom Hold |
Yes |
--- |
Yes |
--- |
Yes |
--- |
|
Top/Valley Hold |
Yes |
--- |
Yes |
--- |
Yes |
--- |
|
User Adjustment |
Yes |
|
Top/Valley Count |
--- |
|
Temperature Range Total
Time Count |
--- |
|
Input Temperature
Variation Detection |
--- |
|
Input Error Detection
Disable Function |
--- |
Note: The Contact Operation Monitor and the
Total ON Time Monitor cannot be used at the same time for the same
contact.
Yes: Supported, ---: Not
supported
|
Function |
Analog I/O Slave Units
(Numerical indicator type) |
Temperature Input Units |
|
Units with e-CON Connectors |
Units with MIL Connectors |
CRT1-TS04T
CRT1-TS04P |
CRT1-VAD02SD CRT1-VDA02SD |
CRT1-VAD02MLD CRT1-VDA02MLD |
|
Input Units |
Output Units |
Input Units |
Output Units |
Input Units |
|
Operation Time Monitor |
--- |
--- |
|
Contact Operation
Monitor (See note.) |
--- |
--- |
|
Total ON Time Monitor
(See note.) |
--- |
--- |
|
Automatic Baud Rate
Detection |
Yes |
Yes |
|
Unit Conduction Time
Monitor |
Yes |
Yes |
|
Naming Units |
Yes |
Yes |
|
Naming Connected
Devices |
Yes |
Yes |
|
Network Power Voltage
Monitor |
Yes |
Yes |
|
I/O Power Status
Monitor |
--- |
--- |
|
Communications Error
History Monitor |
Yes |
Yes |
|
Input Filter |
--- |
--- |
|
Communications Error
Output |
--- |
Yes |
--- |
Yes |
--- |
|
Preventing Malfunctions
Caused by Inrush Current at I/O Startup |
--- |
--- |
|
Power Short-circuit
Detection |
--- |
--- |
|
Unconnected Line
Detection |
--- |
--- |
|
Load Short-circuit
Detection |
--- |
--- |
|
Disconnected Line
Detection |
Yes |
--- |
Yes |
--- |
Yes |
|
Removable Terminal
Block Structure |
Yes |
Yes |
|
Expansion Using
Expansion Units |
--- |
--- |
|
Scaling |
Yes |
Yes |
|
Last Maintenance Date |
Yes |
Yes |
|
Cumulative Count |
Yes |
Yes |
|
Moving Average |
Yes |
--- |
Yes |
--- |
Yes |
|
Setting the Number of
AD Conversion Points |
Yes |
--- |
Yes |
--- |
--- |
|
Rate of Change |
Yes |
--- |
Yes |
--- |
Yes |
|
Comparator |
Yes |
--- |
Yes |
--- |
Yes |
|
Peak/Bottom Hold |
Yes |
--- |
Yes |
--- |
Yes |
|
Top/Valley Hold |
Yes |
--- |
Yes |
--- |
Yes |
|
User Adjustment |
Yes |
Yes |
|
Top/Valley Count |
--- |
Yes |
|
Temperature Range Total
Time Count |
--- |
Yes |
|
Input Temperature
Variation Detection |
--- |
Yes |
|
Input Error Detection
Disable Function |
--- |
Yes |
Note: The Contact Operation Monitor and the
Total ON Time Monitor cannot be used at the same time for the same
contact.
Yes: Supported, ---: Not
supported
|
Function |
Bit Slave Units |
Bit Slaves with Compact
Connectors |
Repeater Unit |
|
CRT1B-[]D02S(-1) |
CRT1B-[]D02JS(-1) |
CRT1B-[]D04JS(-1) |
CRS1-RPT01 |
|
Input Units |
Output Units |
Input Units |
Output Units |
I/O Units |
Input Units |
Output Units |
I/O Units |
|
Operation Time Monitor |
Yes |
--- |
--- |
--- |
|
Contact Operation
Monitor (See note.) |
Yes |
--- |
--- |
--- |
|
Total ON Time Monitor
(See note.) |
Yes |
--- |
--- |
--- |
|
Automatic Baud Rate
Detection |
Yes |
Yes |
Yes |
Yes |
|
Unit Conduction Time
Monitor |
Yes |
--- |
--- |
Yes |
|
Naming Units |
Yes |
--- |
--- |
Yes |
|
Naming Connected
Devices |
Yes |
--- |
--- |
--- |
|
Network Power Voltage
Monitor |
Yes |
--- |
--- |
Yes |
|
I/O Power Status
Monitor |
--- |
--- |
--- |
--- |
|
Communications Error
History Monitor |
Yes |
--- |
--- |
Yes |
|
Input Filter |
Yes |
--- |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
--- |
|
Communications Error
Output |
--- |
Yes |
--- |
Yes |
Yes |
--- |
Yes |
Yes |
--- |
|
Preventing Malfunctions
Caused by Inrush Current at I/O Startup |
Yes |
--- |
--- |
--- |
--- |
|
Power Short-circuit
Detection |
Yes |
--- |
--- |
--- |
--- |
|
Unconnected Line
Detection |
--- |
--- |
--- |
--- |
|
Load Short-circuit
Detection |
--- |
Yes |
--- |
--- |
--- |
|
Disconnected Line
Detection |
--- |
--- |
--- |
--- |
|
Removable Terminal
Block Structure |
--- |
--- |
--- |
--- |
|
Expansion Using
Expansion Units |
--- |
--- |
--- |
--- |
|
Scaling |
--- |
--- |
--- |
--- |
|
Last Maintenance Date |
Yes |
--- |
--- |
Yes |
|
Cumulative Count |
--- |
--- |
--- |
--- |
|
Moving Average |
--- |
--- |
--- |
--- |
|
Setting the Number of
AD Conversion Points |
--- |
--- |
--- |
--- |
|
Rate of Change |
--- |
--- |
--- |
--- |
|
Comparator |
--- |
--- |
--- |
--- |
|
Peak/Bottom Hold |
--- |
--- |
--- |
--- |
|
Top/Valley Hold |
--- |
--- |
--- |
--- |
|
User Adjustment |
--- |
--- |
--- |
--- |
|
Top/Valley Count |
--- |
--- |
--- |
--- |
|
Temperature Range Total
Time Count |
--- |
--- |
--- |
--- |
|
Input Temperature
Variation Detection |
--- |
--- |
--- |
--- |
|
Input Error Detection
Disable Function |
--- |
--- |
--- |
--- |
Note: The Contact Operation Monitor and the
Total ON Time Monitor cannot be used at the same time for the same
contact.
|