Find the Location of a Leak.
Even unseen places under the floor can be pinpointed
and restored.

Liquid leakage locations are displayed in meters. The meter displays can
be converted into area displays for up to 20 areas. In addition, the
Sensor can be used in combination with a touch panel to visually display
the leakage location as seen from the floor.
Observe Changes in the Extent
of Leakage.
Detection of the extent of leakage and occurrence of
a leak in another place.

With previous Sensors, when leakage occurred at a second location after
having first been detected at one location, the position display for the
first location was changed and the display value became unreliable. The
client had to guess at the position of the leakage. With the K7L-UP, the
position display for the first leak remains unchanged even when a second
leak is detected.
Note: The values in parentheses represent the second leakage location
(reference value) after the leakage at the first location has been wiped
off.
Leakage Can Be
Monitored at Long Distance.
Monitoring at Up to 600 m with a Single Sensor.

Liquid leakage sensor cable and general-purpose cable can be combined for
a total length of up to 600 m. Being able to efficiently combine these
cables helps lower costs.
Can Be Used in a
Clean Room.
The liquid leakage sensor cable is made of
fluorocarbon resin for worry-free use.

The liquid leakage sensor cable is made of fluorocarbon resin with
chemical-resistant materials. There is little out gas and it can be used
without worry in a clean room.
Easy to Use
Connectors make it easy to connect and disconnect.

Installation and replacement are made easy with connectors. In addition,
flexible cables make wiring easy.
The Starting
Position for Leakage Monitoring Can Be Shifted.
The location of the leakage detection is now easier
to understand.

This function changes the 0-m position for the sensor cable. When there is
a distance between the K7L-UP and the place where the leakage is detected,
the display can be made easier to understand by changing any distance to 0
m.
Compensation Is
Enabled for Discrepancies between Blueprints and Actual Sites.
Compensation can be used to adjust for actual site
conditions.

This function changes the length of the sensor cable to any value. When
there is a discrepancy between the actual length and the measured length,
this figure can be compensated to any value.
Connect to
Essentially Any Device.
A Wide Selection of Outputs from a Relay Output to
Communications Output to Suit the System.

Relay outputs (NO/NC) and 4 to 20-mA outputs are supported, as well as
RS-485 communications (CompoWay/F and Modbus), making it easy to connect
to a PLC or touch panel.
Suitable for Use
Around the World.
The Sensor conforms to international safety
standards, and the display can be switched between English and Japanese.

The Sensor can be used with assurance that it conforms with CE standards
and cUL standards. In addition, support of English and Japanese displays
and a wide power supply range (100 to 240 AC) allow it to be used
worldwide.
Easy Setup
Setup software makes installation easy.

Even for multiple Sensors, free setup software can be downloaded to make
the setup easy.
|