The next-generation platform for a wide range of sensing
Features a Power Tuning function that
optimizes light reception at the press of a button.
Combines newly developed 4-element LEDs with
an APC circuit to ensure stable, long-term LED performance.
Utilizes OMRON's innovative wire-saving
connector.
2-channel models achieve the thinnest
profile in the industry, at only 5 mm per channel.
2-channel models also offer AND/OR control
output.
|
|
Features |
|
Industry's
First Power Tuning Function in a Digital Sensor
No
complicated mode settings.
(Patent
Pending)
Troublesome power adjustments have been eliminated, so it isn't necessary to select from power mode settings, such as long- distance mode, standard mode, and short- distance mode. When the MODE Key is pressed once, the power tuning function shifts the power level so that the present incident level is set to the ideal level (2000 on the digital display.)
|
Insufficient light or
saturation at short distances can be corrected.
The power tuning range is extended to the allowable limits to eliminate problems such as insufficient light or detection failures due to saturation. If the installation distance is too short, the incident light may saturate (i.e., to a digital incident level of 4,000), preventing detection. The power can be tuned down to 1/ 25th of the default setting for stable detection even at close range.

|
Variations between
different Sensors can be eliminated.
Threshold levels had to be set and maintained separately for individual Sensors due to variations in the digital light levels measured by each Sensor. With power tuning, the incident level can be fine-tuned so the same threshold level can be set for each Sensor in an application. Maintenance is also simplified because it is easier to recognize measurement levels that have shifted during operation.

|
|
Large,
Easy-to-Read Displays: Clear Even from a Distance
The displays are large and easy-to-read, despite the small case.
Settings can be made more simply and confidently with two digital displays. For example, the
threshold value can be changed while reading the incident level or a setting can be changed while
confirming the setting's function item number.

|
|
Seven
Convenient Display Formats
(Patent
Pending)
An incident level/ threshold display,
percentage/ threshold display, and large bar graph display have been
added, so you can select the best display method for the application.
|
|
Stable,
Long-term Performance with APC Function
OMRON provides the
industry's most stable long-term detection by using new 4-element LEDs and
an APC (Auto Power Control) circuit.
(Highest
Level of Stability)
In addition to our unique APC circuit used in the E3X-DA-N Amplifiers to compensate for the deterioration of the LED, the E3X- DA- S uses 4-element LEDs to counteract the deterioration of the light-emitting elements over time and achieve the industry's most stable long-term detection performance.
Furthermore, the circuit is designed with excess light capacity, so the Sensors can be used with
high stability regardless of whether the APC circuit is ON or OFF.

|
Compensate for the
effects of contaminants and temperature variation with different operation
mode. (Advanced Models)
This operation mode uses a special OMRON algorithm to compensate for slight light level changes due to dirt or temperature variations and detect only the light level changes due to the workpiece.
Slight light level changes can be detected with stability and precision, eliminating the need for time-consuming manual adjustments for light level changes.
With the Twin-output Amplifiers, output 2 can function as an alarm output (light level operation) to indicate when the light level has changed due to dirt or other causes.
(Patent Pending)

|
|
Many
Advanced Functions for Even More Applications
In super-high-speed mode, it
is the fastest digital model at 48 µs. (Standard Models) (Fastest
in the Industry)
Provides high-speed response for miniature
workpieces, such as chip parts and devices with short tact times.
Three kinds of timers functions are
supported. The timers can be set between 1 ms and 5 s. A one-shot timer is
supported in addition to the ON-delay and OFF-delay timers. The
Amplifier's ON time can be fixed, which is useful during high-speed
workpiece detection.
|
|
Area
output function can be used for range judgment. (Advanced Twin-output
Models)
|
|
Operations that required multiple Sensors, such as height measurement, can be performed with just one Sensor. Two threshold levels can be set to easily output within-range and out-of-range outputs.
|
 |
Remote
input function can control the Sensor remotely. (Advanced External-input
Models)
Input signals can make various remote settings, such as teaching operations, power tuning, and emitter OFF. This model is ideal for diverse needs, such as checking Sensor operation remotely before operation or making settings remotely because teaching has to be performed often for frequent workpiece model changes.
|
The
counter function can output signal after counter counts up or down.
(Advanced External-input Models)
(Patent
Pending)
A counter function is built-in, so the number of workpieces can be counted without a separate counter or small PLC that used to be required.

|
|
The
Same Ease-of-Use as the E3X-DA-N
The E3X-DA-S uses
OMRON's own simplified wiring connectors that were introduced with the
E3X-DA-N.
(Patent
Pending)
In Amplifiers with Connectors, the power supply is distributed to slave connectors through a single master connector. This design has three major advantages.
-
Wiring time is significantly reduced.
-
Relay connectors are unnecessary, so wiring takes up less space.
-
Storage and maintenance are simpler because it isn't necessary to
distinguish between master connector and slave connectors on the Amplifier.
|
|
Optical communications
prevents mutual interface.
Mutual interference is prevented with optical communications, so up to 10 Amplifiers can be mounted together.
(The number of Amplifiers depends on the operating conditions.)

|
|
Zero reset function
immediately resets the digital display to 0.
(Patent
Pending)
The zero reset function can immediately reset the digital display to 0 at any time. By setting the reference value to 0, the threshold value can be set while monitoring differences in incident light levels. The threshold value will also shift simultaneously when the zero reset button is pressed.

|
|
Reversible Digital
Display (Reverse Mode)
|
|
The digital display can be reversed to
match the Amplifier's mounting direction.
|
|
|
Environmentally
Friendly Design
1
Materials containing
lead have been completely eliminated.
|
The Fiber Sensor is the
first in the industry to use environmentally friendly lead-free
solder. |
 |
|
 |
|
|
2
The digital display can
be turned OFF or dimmed during operation.
When the digital display is viewed infrequently during operation, current consumption can be reduced by dimming the display or turning it OFF entirely.
The display will light up again automatically when an operation key is touched. (Eco-mode can be set from the Mobile Console only.)
 |
|
3
Cable disposal is not
required during maintenance.
|
In addition to saving space and reducing wiring time, the new connector design eliminates the need to dispose of cables together with the Amplifiers. |
 |
|
|
Further
Improvements to the Mobile Console
 |
|
Group
Power Tuning
With the group power tuning
function, power tuning is possible for multiple Sensors at the same
time.

|
|
Improved
Mode Lock Function
Settings can be customized
for different applications by locking out unnecessary function blocks
within function settings.

|
|
Retains all of the
Previous Advantages of the Mobile Console.
Settings, teaching
and fine-tuning can be perform at the fiber tip
The Mobile Console can be used for settings and teaching at the tip of the fiber. Difficult adjustments can be made while checking the workpiece position.
Even if the Amplifier and Sensor head are separated during operation, it is still possible to flash the Sensor head and display the amplifier channels.
|
 |
With Group
Teaching, Teach Multiple Amplifiers Simultaneously
With the group power tuning function, power tuning is possible The tedious teaching that had to be performed separately for each Amplifier can now be performed for several Amplifiers at once using the Mobile Console.
|
 |
Copying Settings within the Same Group
Settings such as mode or threshold settings in an Amplifier or bank can be copied to all of the Amplifiers in the same group.
|
 |
Copying Settings to Other Groups
The settings for a group of Amplifiers on one machine can be copied to a group of Amplifiers on another machine. (The settings can also be copied to and from banks.)
|
 |
|
|
|
|
|
Application Examples |
|
 

|
|
top |
|
 |
|