FAQ No. FAQ03429
Question
Why does the ERR signal come ON without displaying a Vision Sensor error
message?
Answer
If a STEP signal (trigger to perform measurement) is input while the BUSY
signal (indicates that it is processing the measurement) is ON, the ERR
signal (error) comes ON and stays ON. If the STEP signal is input again
after the BUSY signal has gone OFF, the ERR signal goes OFF and
measurement is performed.
You can choose whether or not to turn ON the ERR signal in the System/
Measurement Control options. The default setting is to turn ON the ERR
signal.
This is applicable to all models subsequent to the F150 Vision Sensor.
These are the F150, F160, F180,
F210, F250, F270, F400, and
F500.
Other Vision Sensor
FAQs
Can the Vision Sensor Console Cable be extended?
How can a stored image that is displayed on the F160 be re-measured?
Is there a F150-VS Camera Cable that can withstand bending?
|